A side-by-side look at the Aeroz and Predictive Maintenance MCP Server MCP servers: transport, auth, tools, quality signals, and the config to install either one in Claude, Cursor, Windsurf or VS Code.
Verdict: choose Aeroz for industrial & iot work over a hosted endpoint; choose Predictive Maintenance MCP Server for industrial & iot as a local process. You can also run both side by side in one mcpServers block.
PSA_API_TOKEN.verify_chip, check_recall, dpp_readiness.list_signals, generate_test_signal, load_signal.Rows where the two servers differ are marked.
| Spec | A Aeroz | |
|---|---|---|
| Category | Industrial & IoT | Industrial & IoT |
| Quality signal | 51/100 · Good | 63/100 · Good |
| Install command | Confirmed | Confirmed |
| Transport | Remote HTTP/SSE | Local subprocess (stdio) |
| Auth | Not declared | Not declared |
| Pricing | Not declared | Not declared |
| Required env vars | PSA_API_TOKEN | None listed |
| Verified owner | Community listing | Community listing |
| GitHub stars | — | 105 |
| Directory activity | 0 views 0 installs 0 upvotes | 1 views 0 installs 0 upvotes |
| Tools | 30 | 34 |
| Full listing | View Aeroz | View Predictive Maintenance MCP Server |
verify_chipVerify a physical item by its Aeroz chip: the UID plus whatever signature the tap carried. Same answer as GET /v1/verify. Use this before trusting any claim about a physical unit — a database record proves a record exists, not that the object in front of you is the one it describes. Read `proof` and `proves`: proof "presence" means the chip answered a fresh one-time SUN challenge (picc_data + cmac) and was physically there at this tap; proof "identity" means the static `t` signature is the one Aeroz issued for this UID, which a copied tag also carries. verified:false with reason "no_signature" (recognised:true) proves NOTHING about the item — only that the number is on the register. "signature_unchecked" means the signature was not compared (not a mismatch). A failed signature returns NO product data. Each call records the tap and spends the chip's one-time answer, so pass each SUN tap once. A sandbox key answers its seeded sandbox chips as fixtures (mode "sandbox" with a _warning) and any other UID from the register (mode "sandbox", register:true), so a sandbox company can check the test tags it minted.check_recallCheck whether a specific unit is subject to an active recall, from the register: reads only, verifies no signature and spends no chip answer. Returns known (on the register), recalled, and the recall reason, severity, date and id when one applies. recalled:null means the status is UNKNOWN (the UID is not on the register, or the register could not be read) — never report that as "not recalled". This says nothing about whether the item is genuine; use verify_chip for that. Use whenever a unit is about to be shipped, sold, dispensed, or installed. A sandbox key answers its seeded sandbox chips first and any other UID from the register (register:true).dpp_readinessAssess how ready a product category is for an EU Digital Product Passport, against the delegated act that applies to it. Returns the required data fields, which are present, and which are missing. IMPORTANT: this is a readiness signal, not a legal compliance determination — never report its output as confirmation that a product is compliant.list_findingsList findings raised by the Aeroz compliance agents watching this organisation — recall hits, DPP data gaps, regulatory changes, dwell anomalies, and clone detections. Use this to answer "what needs my attention".list_agentsList the Aeroz compliance agents available to this organisation and which are currently enabled. Use this to explain monitoring coverage or to find an agent worth enabling.get_usageReturn this organisation's Aeroz verification volume and outcome breakdown over a recent period. Use for reporting on scan volume, authentication failure rates, and trend. The buckets — authentic, recalled (any tap whose answer carried a recall, verified or not), mismatched (failed static or SUN signature), not_found, unverified (no or unchecked signature, test tag, held or disabled unit) and other — always sum to total.list_sandbox_chipsList the seeded sandbox chips for this organisation, with the UID and signature to pass to verify_chip, one per scenario: authentic, recalled, signature_mismatch (listed with a deliberately WRONG signature) and not_found (a UID that is not on the register). Sandbox only — use when building or testing an integration before physical chips ship.onboarding_statusReport where this organisation stands in Aeroz onboarding: current stage, percentage complete, health, the single next action, and every open step with which side owns it. Use this to answer "what do we still need to do", "why are we not live yet", or "what is Aeroz waiting on". Steps marked side="aeroz" are Aeroz's obligation, not the customer's — say so plainly rather than presenting them as homework.onboarding_next_stepReturn only the single most important next action and how to complete it. Use when the user asks what to do next and does not want the whole checklist.complete_onboarding_stepMark a manual onboarding step complete on behalf of this organisation. Only steps the customer owns and that Aeroz cannot verify automatically can be set this way; an automatically verified step will refuse, because a self-report that contradicts the platform data is worse than no report. Pass the step key from onboarding_status.business_briefThe full picture of this business as Aeroz holds it: declared product categories with their mandate dates and whether each date is fixed or provisional, onboarding state, open findings, and — importantly — which recall sources are NOT being monitored. Use this to orient before answering anything about the account. Never present an empty findings list as evidence of safety without also reporting coverage_gaps.ask_agentAsk this organisation's dedicated Aeroz agent a question in plain language and get a grounded answer. Use it for anything a human at the business would ask their account manager: "what do we still need to do", "when is our deadline", "what is Aeroz waiting on", "what is not being monitored", "how do we go live". The answer carries `grounded`: `computed` means it was read directly from the account's own data; `model` means a model composed it from that data and every date and figure was checked against it; `declined` means the agent does not hold what the question needs and said so — relay that honestly rather than filling the gap yourself. Asking refreshes the account's onboarding state and records the question and answer in the conversation (see agent_conversation). It sends nothing outside Aeroz and changes no product, shipment or passport data.list_signalsList signal files on disk or signals loaded in the repository.
scope='disk' (default): files under data/signals/ that load_signal can
open — use before loading. scope='memory': signals currently cached in
the in-memory repository with their metadata (signal_id, sampling_rate,
declared unit) — use to see which signal_ids are available for analysis.
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
scope: 'disk' for loadable files, 'memory' for loaded signal_ids.
Returns:
Dict with scope, count, and either 'files' (relative paths, disk)
or 'signals' (StoredSignalInfo entries, memory).
generate_test_signalGenerate a synthetic test signal, save it, and load it into the repository.
The signal is written to data/signals/ with a timestamped filename and a
companion _metadata.json declaring sampling_rate and signal_unit='g'
(synthetic acceleration), then auto-registered in the repository — the
returned signal_id is immediately usable by every analysis, diagnosis,
and ISO severity tool with no manual steps.
Signal content: 'bearing_fault' = 10 Hz impacts modulating a 1 kHz
carrier; 'gear_fault' = 200 Hz mesh tone + harmonics; 'imbalance' =
25 Hz (1500 RPM) tone; 'normal' = broadband noise.
Args:
signal_type: Synthetic fault pattern to generate.
duration: Signal duration in seconds (10 s gives 0.1 Hz resolution).
sampling_rate: Sampling frequency in Hz.
noise_level: Additive white-noise amplitude.
random_seed: Seed for reproducible noise (None = non-deterministic).
ctx: MCP context. Unused — see this module's docstring on logging.
Returns:
StoredSignalInfo of the auto-loaded signal (signal_id, declared
sampling_rate and unit 'g').
load_signalLoad one signal — or a batch — into the in-memory repository.
Once loaded, reference the signal by its signal_id in every analysis,
diagnosis, report, and prognostics tool (the load -> analyze ->
diagnose -> report flow uses signal_id as the single handle).
Batch form: pass a LIST of file paths (e.g. for training sets). The
batch is fail-fast and atomic — all paths and derived ids are
validated up front, and on the first problem ONE error names the
offending entries and nothing is loaded. One declared sampling_rate/
signal_unit applies to all files; per-file metadata wins only when
the parameter is omitted. Custom signal_id is not allowed for a
batch (ids derive from each file's relative path).
signal_id default: the path relative to data/signals/ with separators
replaced by underscores — 'real_train/baseline_1.csv' loads as
'real_train_baseline_1', so same-named files in different folders
never collide silently. Re-loading a path whose id already exists is
an explicit error unless overwrite=True.
Signal unit discipline: ISO 20816-3 severity verdicts require a
DECLARED unit — either via this parameter or a 'signal_unit' field in
the companion _metadata.json (explicit parameter wins). Units are
never guessed from signal amplitude; without a declared unit the ISO
severity block is refused with a structured reason and remedy.
Raw binary files (.bin/.raw/.dat): a headerless raw waveform loads
only with a declared decode contract — sample_format AND
sampling_rate are REQUIRED, either as explicit parameters here or as
fields of the companion <stem>_metadata.json next to the file
(explicit parameter wins). The other raw parameters carry documented
defaults, applied by the repository after that merge: byte_order
'little', n_channels 1, channel_index 0, header_offset 0, no
scale_factor. Integer sample formats (int16/int32) decode to raw ADC
counts — declare scale_factor to convert counts into the declared
physical unit (there is no implicit normalization). In a batch the
raw parameters broadcast to ALL files, exactly like sampling_rate.
Declaring raw parameters for a self-describing format (.csv, .npy,
...) is refused as a contradiction. With n_channels > 1 each load
extracts ONE channel and the DERIVED id gains a _ch<channel_index>
suffix; an explicit signal_id is used verbatim — no suffix applies.
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
filepath: Filename relative to data/signals/ or absolute path —
or a list of such paths for an atomic batch load.
signal_id: Custom ID (single-file loads only; default derives
from the relative path).
sampling_rate: Sampling rate in Hz (overrides metadata file).
Required for raw binary files (here or in the companion).
signal_unit: Declared signal unit — 'g' or 'm/s2' (acceleration),
'mm/s' or 'm/s' (velocity). Overrides the metadata file.
overwrite: Replace existing entries on signal_id collision
instead of raising.
sample_format: Raw files only — declared sample dtype ('float32',
'float64', 'int16', 'int32'). REQUIRED for .bin/.raw/.dat
(here or in the companion metadata).
byte_order: Raw files only — declared endianness ('little' or
'big'); documented default 'little'.
n_channels: Raw files only — interleaved channel count in the
file; documented default 1.
channel_index: Raw files only — 0-based channel to extract;
documented default 0.
header_offset: Raw files only — bytes to skip before the first
sample; documented default 0.
scale_factor: Raw files only — optional multiplier applied after
decoding (e.g. ADC counts -> physical unit); default: no
scaling.
Returns:
StoredSignalInfo for a single load; a list of StoredSignalInfo
(input order) for a batch. Raw loads record the effective decode
parameters under raw_format.
Raises:
ValueError: If signal_unit is invalid, the signal data cannot be
loaded, a signal_id collides without overwrite=True, a batch
contains any invalid entry (nothing is loaded), a raw binary
file is missing a required declaration (ONE message names
everything missing plus both remedies), or raw parameters
are declared for a self-describing format.
get_signal_infoGet metadata for a stored signal without loading the full array.
Includes the COMPLETE companion-metadata dict (source_metadata: rpm/
shaft_speed, reference frequencies, ...) alongside the repository
fields (sampling_rate, declared signal_unit, shape, timestamps).
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
signal_id: ID of a signal previously loaded via load_signal.
Returns:
StoredSignalInfo with source_metadata populated from the companion
_metadata.json (empty dict when the file has none).
Raises:
ValueError: If the signal_id is not in the repository.
clear_signalsRemove one signal — or all signals — from the in-memory repository.
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
signal_id: ID to remove; None (default) clears the whole cache.
Returns:
Dict with cleared_count, plus signal_id and status ('removed' or
'not_found') for single-signal calls.
analyze_fft
Perform FFT (Fast Fourier Transform) analysis on a stored signal.
FFT analysis converts the signal from time domain to frequency domain,
allowing identification of harmonic components and faults that manifest
at specific frequencies. Requires the signal loaded via load_signal()
first; the sampling rate comes from the stored signal metadata.
By default analyzes the LEADING 1.0-second segment (deterministic:
two identical calls return identical results). Set
segment_duration=None to analyze the entire signal, or pass
random_seed to sample a seeded random segment position instead.
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
signal_id: ID of the stored signal (from load_signal).
max_frequency: Maximum frequency to analyze (default: Nyquist frequency)
segment_duration: Duration in seconds to analyze (default: leading
1.0 s). Set to None to analyze the full signal.
random_seed: Seed for random segment position (default: None =
deterministic leading segment).
Returns:
FFTResult with top peaks, dominant peak, and spectrum stats.
Raises:
ValueError: If the signal_id is not loaded, or the stored signal
has no sampling rate.
analyze_envelope
Envelope-spectrum analysis of a stored signal (bearing fault screening).
THE unified envelope tool: bandpass filter -> Hilbert
envelope -> mean subtraction + Hann window -> FFT -> top peaks.
The mean subtraction/window step is an intentional U9 fix: the
envelope's DC leakage used to bury the low-frequency FTF zone.
Requires the signal loaded via load_signal() first; the sampling
rate comes from the stored signal metadata.
The requested band must fit the signal: an invalid band (low <= 0,
low >= high, high > Nyquist) raises a ValueError — it is NEVER
silently clamped. The band used is echoed in the result.
By default analyzes the LEADING 1.0-second segment (deterministic:
two identical calls return identical results). Set
segment_duration=None to analyze the entire signal, or pass
random_seed to sample a seeded random segment position instead.
No reference bearing frequencies are assumed: compare the returned
peaks against frequencies computed for the actual bearing and
shaft speed (check_bearing_faults or
calculate_bearing_characteristic_frequencies).
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
signal_id: ID of the stored signal (from load_signal).
filter_low: Bandpass low edge in Hz (default: 500).
filter_high: Bandpass high edge in Hz (default: 5000). Must
not exceed the signal's Nyquist frequency.
num_peaks: Number of top peaks to return (default: 5).
segment_duration: Duration in seconds to analyze (default:
leading 1.0 s). None analyzes the full signal.
random_seed: Seed for random segment position (default: None =
deterministic leading segment).
Returns:
EnvelopeResult with the band actually used, top peaks, and
comparison guidance.
Raises:
ValueError: If the signal_id is not loaded, the stored signal
has no sampling rate, or the band is invalid vs Nyquist.
analyze_statistics
Calculate statistical parameters of a stored signal for diagnostics.
Statistical parameters are key indicators for diagnostics:
- RMS: Effective value, correlated to signal energy
- Crest Factor: Indicates presence of impulses (high = possible faults)
- Kurtosis: Measures impulsiveness (excess kurtosis; >0 = non-Gaussian, >3 = strong impulses)
- Peak-to-Peak: Signal range
Requires the signal loaded via load_signal() first. Statistical
parameters are screening indicators, not definitive diagnostics —
combine with frequency-domain evidence.
**Signal units:** all values are in the signal's native unit. The unit
is reported only when DECLARED — load_signal(signal_unit=...) or the
companion _metadata.json — and never guessed from signal amplitude.
ISO 20816-3 severity tools refuse to produce a verdict until the unit
is declared.
Args:
signal_id: ID of the stored signal (from load_signal).
Returns:
StatisticalResult with all statistical parameters
Raises:
ValueError: If the signal_id is not loaded.
extract_features_from_signal
Extract time-domain features from a stored signal using sliding windows.
Segments the signal into overlapping windows and extracts 17 statistical features
from each segment. Features include: mean, std, RMS, kurtosis, crest factor, entropy, etc.
Requires the signal loaded via load_signal() first; the sampling rate
comes from the stored signal metadata. Returns an in-memory summary
only — no CSV is written to data/signals/.
Args:
signal_id: ID of the stored signal (from load_signal).
segment_duration: Duration of each segment in seconds (default: 0.1)
overlap_ratio: Overlap between segments, 0-1 (default: 0.5 = 50%)
ctx: MCP context. Unused — see this module's docstring on logging.
Returns:
FeatureExtractionResult with features matrix and metadata
Raises:
ValueError: If the signal_id is not loaded, or the stored signal
has no sampling rate.
Example:
extract_features_from_signal(
"healthy_motor",
segment_duration=0.2,
overlap_ratio=0.5
)
compute_power_spectral_densityCompute Power Spectral Density (Welch method) for a stored signal.
Requires signal loaded via load_signal() first.
Args:
signal_id: ID of the stored signal.
nperseg: Samples per FFT segment (default 256).
noverlap: Overlap between segments (default 128).
window: Window function (default 'hann').
compute_spectrogram_stftCompute STFT spectrogram for a stored signal.
Returns time-frequency summary (no full 2D array). Use for detecting
time-varying frequency content (transient faults, speed changes).
Args:
signal_id: ID of the stored signal.
nperseg: Samples per STFT segment (default 256).
noverlap: Overlap between segments (default 128).
window: Window function (default 'hann').
assess_severityAssess vibration severity (ISO 20816-3 zones A-D) and alert level.
THE unified severity tool: ISO zone assessment and alert
classification in one call. Zone boundary values are those of
ISO 10816-3:2009 (ISO 20816-3:2022 merges zones A/B — provenance is
noted in the result). Scope: machines rated above 15 kW; a declared
machine_power_kw below 15 kW is refused.
Input routes (exactly ONE required):
- signal_id: a stored signal (load_signal first). Sampling rate AND
declared unit come from the stored metadata; an undeclared unit is
refused, never guessed from amplitude.
- rms_velocity_mm_s: a direct broadband RMS velocity reading in mm/s
(e.g. from a portable instrument) — no unit declaration needed.
Args:
ctx: MCP context. Unused — see this module's docstring on logging.
signal_id: ID of the stored signal (mutually exclusive with
rms_velocity_mm_s).
rms_velocity_mm_s: Direct broadband RMS velocity in mm/s
(mutually exclusive with signal_id).
machine_group: 1 (large, >300 kW) or 2 (medium, 15-300 kW).
Ignored when custom thresholds are given. Default 2.
support_type: 'rigid' or 'flexible'. Ignored when custom
thresholds are given. Default 'rigid'.
thresholds: Optional custom zone boundaries {'warning': A/B,
'alarm': B/C, 'danger': C/D} in mm/s, strictly increasing —
replaces the ISO table for this call.
machine_power_kw: Rated machine power, if known. Declared values
below 15 kW are refused (out of ISO scope); None means
unknown and is not refused.
rpm: Operating speed in RPM (signal route only: selects the 2 Hz
band lower edge below 600 RPM).
Returns:
VibrationSeverityResult (status='assessed') with zone, severity,
boundaries, derived alert_level/exceeded_threshold, and threshold
provenance.
Raises:
ValueError: On route misuse (both/neither inputs), undeclared
signal unit, missing sampling rate, Nyquist below the ISO
band, declared power below 15 kW, negative RMS, or invalid
custom thresholds.
Paste either block (or both) into your client config, e.g. claude_desktop_config.json or ~/.cursor/mcp.json. We only show a config when the install command is confirmed.
{
"mcpServers": {
"aeroz": {
"command": "npx",
"args": [
"-y",
"aeroz"
],
"env": {
"PSA_API_TOKEN": "YOUR_PSA_API_TOKEN_HERE"
}
}
}
}
{
"mcpServers": {
"predictive-maintenance-mcp-server": {
"command": "uvx",
"args": [
"predictive-maintenance-mcp"
]
}
}
}