zw008/VMware-Storage
π βοΈ - VMware vSphere storage management β datastores (NFS/VMFS), iSCSI software adapter and dynamic targets, and vSAN cluster operations. 11 tools with dry-run preview and double-confirmation for iSCSI configuration changes.
Quick Install
{
"mcpServers": {
"zw008-vmware-storage": {
"command": "npx",
"args": [
"-y",
"zw008-vmware-storage"
]
}
}
}Using an AI coding agent (Claude Code, Cursor, etc.)? Copy a ready-made prompt that tells it to fetch the setup instructions and install this server for you.
Documentation Overview
VMware Storage
Author: Wei Zhou, VMware by Broadcom β wei-wz.zhou@broadcom.com This is a community-driven project by a VMware engineer, not an official VMware product. For official VMware developer tools see developer.broadcom.com.
VMware vSphere storage management: datastores, iSCSI, vSAN β 11 MCP tools, domain-focused and lightweight.
Split from vmware-aiops for lighter context and local model compatibility.
Companion Skills
| Skill | Scope | Tools | Install |
|---|---|---|---|
| vmware-aiops β entry point | VM lifecycle, deployment, guest ops, clusters | 49 | uv tool install vmware-aiops |
| vmware-monitor | Read-only monitoring, alarms, events, VM info | 27 | uv tool install vmware-monitor |
| vmware-vks | Tanzu Namespaces, TKC cluster lifecycle | 20 | uv tool install vmware-vks |
| vmware-nsx | NSX networking: segments, gateways, NAT, IPAM | 33 | uv tool install vmware-nsx-mgmt |
| vmware-nsx-security | DFW microsegmentation, security groups, Traceflow | 21 | uv tool install vmware-nsx-security |
| vmware-aria | Aria Ops metrics, alerts, capacity planning | 28 | uv tool install vmware-aria |
Quick Install
# Via PyPI
uv tool install vmware-storage
# Or pip
pip install vmware-storage
Offline / Air-Gapped Install (from source)
This project uses the modern PEP 517 build system (hatchling), so there is no
setup.py by design β that is expected, not a missing file. If you cloned the
source and hit ERROR: File "setup.py" or "setup.cfg" not found ... editable mode currently requires a setuptools-based build, your pip is older than 21.3 and
cannot do an editable (-e) install with a non-setuptools backend. Editable
mode is a developer convenience, not needed to run the tool β do one of:
# From the source tree β a normal (non-editable) install builds a wheel:
pip install . # NOT pip install -e .
# ...or upgrade pip first, and editable works too:
pip install --upgrade pip && pip install -e .
For a truly air-gapped host, build the wheels on a connected machine and copy them over β the target then needs no network:
# On a connected machine, collect this package + its dependencies as wheels:
pip wheel . -w dist # β dist/*.whl (or: uv build, for just this package)
# Copy dist/ to the air-gapped host, then install offline:
pip install --no-index --find-links dist vmware-storage
Configuration
mkdir -p ~/.vmware-storage
cp config.example.yaml ~/.vmware-storage/config.yaml
# Edit with your vCenter/ESXi credentials
echo "VMWARE_MY_VCENTER_PASSWORD=your_password" > ~/.vmware-storage/.env
chmod 600 ~/.vmware-storage/.env
# Verify
vmware-storage doctor
MCP Tools (11)
| Category | Tools | Type |
|---|---|---|
| Datastore | list_all_datastores, browse_datastore, scan_datastore_images, list_cached_images | Read |
| iSCSI | storage_iscsi_enable, storage_iscsi_status, storage_iscsi_add_target, storage_iscsi_remove_target, storage_rescan | Read/Write |
| vSAN | vsan_health, vsan_capacity | Read |
Auto-Remediation Patterns (PoC)
The patterns/ directory hosts L5 auto-remediation candidate patterns from the Enterprise Harness Engineering framework. The first PoC pattern, patterns/iscsi-target-stale-rescan.yaml, describes an iSCSI HBA rescan as a low-risk, reversible, repeatable operation. The pattern schema is documented here only β runtime enforcement is not yet wired up, so this is a reference design, not production auto-remediation.
Common Workflows
Set Up iSCSI Storage on a Host
- Enable iSCSI adapter:
vmware-storage iscsi enable esxi-01 - Add target:
vmware-storage iscsi add-target esxi-01 10.0.0.100 - Verify:
vmware-storage iscsi status esxi-01
The add-target command automatically rescans storage. Use --dry-run to preview any write command first.
Find Deployable Images Across Datastores
- List all datastores:
vmware-storage datastore list - Scan for images:
vmware-storage datastore scan-images datastore01 - Browse with a pattern:
vmware-storage datastore browse datastore01 --pattern "*.iso"
vSAN Health Assessment
- Check health:
vmware-storage vsan health Cluster-Prod - Check capacity:
vmware-storage vsan capacity Cluster-Prod - If issues found, investigate with
vmware-monitorfor alarms and events
CLI
# Datastore
vmware-storage datastore list
vmware-storage datastore browse datastore01
vmware-storage datastore scan-images datastore01
# iSCSI
vmware-storage iscsi status esxi-01
vmware-storage iscsi enable esxi-01
vmware-storage iscsi add-target esxi-01 192.168.1.100
vmware-storage iscsi remove-target esxi-01 192.168.1.100
vmware-storage iscsi rescan esxi-01
# vSAN
vmware-storage vsan health Cluster-Prod
vmware-storage vsan capacity Cluster-Prod
# Diagnostics
vmware-storage doctor
MCP Server
After uv tool install vmware-storage, start the MCP server with one command (v1.5.15+):
# Recommended β single command, no network re-resolve
vmware-storage mcp
# With a custom config path
VMWARE_STORAGE_CONFIG=/path/to/config.yaml vmware-storage mcp
# Or via Docker
docker compose up -d
Agent Configuration
Add to your AI agent's MCP config:
{
"mcpServers": {
"vmware-storage": {
"command": "vmware-storage",
"args": ["mcp"],
"env": {
"VMWARE_STORAGE_CONFIG": "~/.vmware-storage/config.yaml"
}
}
}
}
Alternative: uvx (no install) or legacy entry point
# Run without installing (requires PyPI access each launch)
uvx --from vmware-storage vmware-storage mcp
# Legacy entry point (still works, kept for backward compatibility)
vmware-storage-mcp
Behind a corporate TLS proxy? uvx may fail with
invalid peer certificate: UnknownIssuer. Use the recommendedvmware-storage mcpform above (no network needed), or setUV_NATIVE_TLS=true.
Why a Separate Skill?
vmware-aiops has 49 MCP tools β too heavy for local LLMs (7B-14B). By splitting storage into its own skill:
- 11 tools β fits comfortably in small model context windows
- Domain-focused β storage admins get only what they need
- Composable β use alongside vmware-monitor or vmware-aiops as needed
Version Compatibility
Python: 3.10+ (since v1.5.27 β previously 3.11+). Tested on 3.10 / 3.11 / 3.12.
| vSphere / VCF | Support | Notes |
|---|---|---|
| VCF 9.1 / vSphere 9.1 | Full | Released 2026-05-12. pyVmomi+vSAN SDK <10.0 works via SOAP. |
| VCF 9.0 / vSphere 9.0 | Full | pyVmomi 8.0.3+ with bundled vSAN SDK connects to vSphere 9. |
| 8.0 | Full | vSAN SDK built into pyVmomi 8.0.3+ |
| 7.0 | Full | All storage APIs work |
| 6.7 | Compatible | iSCSI + datastore features work; vSAN limited |
Official Broadcom References
- SDKs: https://developer.broadcom.com/sdks β VCF Python SDK, vSAN Management SDK (bundled in pyVmomi)
- REST APIs: https://developer.broadcom.com/xapis β vSAN Management API, VCF API
- CLI Tools: https://developer.broadcom.com/tools β PowerCLI 9.1, ESXCLI
Safety
| Feature | Description |
|---|---|
| Read-heavy | 7/11 tools are read-only |
| Input validation | IP addresses and ports validated before iSCSI operations |
| Audit logging | All operations logged to ~/.vmware-storage/audit.log |
| No VM operations | Cannot create, delete, or modify VMs |
| Credential safety | Passwords only from environment variables, never config files |
Troubleshooting
| Problem | Cause & Fix |
|---|---|
| iSCSI enable fails with "already enabled" | Not an error β adapter is already active. Run iscsi status to see configured targets. |
| "Datastore not found" when browsing | Datastore names are case-sensitive. Run datastore list to get the exact name. |
| vSAN health shows "unknown" | vSAN health requires a vCenter connection, not standalone ESXi. |
| Rescan doesn't discover new LUNs | Wait 15-30 seconds after adding targets, then rescan again. Verify target IP is reachable from ESXi. |
| "Password not found" error | Variable names follow VMWARE_<TARGET_UPPER>_PASSWORD (hyphens β underscores). Check ~/.vmware-storage/.env. |
| Connection timeout to vCenter | Use vmware-storage doctor --skip-auth to bypass auth checks on high-latency networks. |
| "Datastore browse did not finish within Ns" | The datastore is very large or busy. Narrow the search with a sub-path and a specific pattern (e.g. datastore browse ds01 --path templates --pattern "*.ova") instead of browsing the root β do not just retry the same broad browse. |