The full upstream README, mirrored here for reference. Install config, tool schemas, adoption signals, and an original overview live on the MCP Hydrolix listing page.
An MCP server for Hydrolix.
Get up and running in a few minutes. This section covers Claude Desktop and Claude Code.
Before you begin, make sure you have:
Choose the method that matches your setup:
Option A: Using uv (recommended)
uv manages Python automatically and downloads mcp-hydrolix on demand, so no separate install step is needed. If you don't have uv, install it:
macOS / Linux:
Windows (PowerShell):
Option B: Using pip
Requires Python 3.13+. If you need to install Python, download it from python.org.
Open the Claude Desktop configuration file:
~/Library/Application Support/Claude/claude_desktop_config.json%APPDATA%\Claude\claude_desktop_config.json~/.config/Claude/claude_desktop_config.jsonAdd the following entry to the "mcpServers" object (create the file with this content if it doesn't exist yet):
Replace <your-hydrolix-hostname>, <your-username>, and <your-password> with your actual credentials.
[!NOTE] If you used Option B (pip), use
"command": "mcp-hydrolix"with no"args"field instead.
[!TIP] If the file already has other entries, add the
"mcp-hydrolix"block inside the existing"mcpServers"object rather than replacing the whole file.
[!NOTE] If you authenticate with a service account token instead of username/password, see Authentication.
Claude Desktop launches without your shell's PATH, so it may not locate the binary even if it is installed. Find the full path and use it as the "command" value in the config.
Option A (uv): find uvx:
which uvxwhere.exe uvxOption B (pip): find mcp-hydrolix:
which mcp-hydrolixwhere.exe mcp-hydrolixIf which/where.exe returns nothing, the binary isn't on your PATH. The cleanest fix is to switch to Option A (uv), which manages the Python environment and PATH for you.
Restart the app to apply the configuration.
macOS / Windows users: Make sure to fully quit Claude before restarting. On macOS, press Cmd+Q or right-click the Dock icon and choose Quit. On Windows, use the system tray icon.
Open a new conversation in Claude Desktop. Look for a tools/hammer icon near the text input — this confirms the MCP server connected successfully.
Try this prompt to confirm everything is working:
Using your Hydrolix MCP tools, list the available databases.
Claude should call the list_databases tool and return a list of databases from your cluster.
If you prefer the command line, make sure uv is installed (Option A from Step 2), then run:
Then open Claude Code and test with the same prompt:
Using your Hydrolix MCP tools, list the available databases.
Click the Install in VS Code badge at the top of this README for a one-click install. If you prefer the UI flow, open the Command Palette (Cmd+Shift+P / Ctrl+Shift+P), run MCP: Add Server, choose Command (stdio), and reuse the uvx ... command and env block from Step 3.
run_select_query
sql (string): The SQL query to execute.list_databases
list_tables
database (string): The name of the database.get_table_info
database (string): The name of the database.table (string): The name of the table.Due to the wide variety in LLM architectures, not all models will proactively use the tools above, and few will use them effectively without guidance, even with the carefully-constructed tool descriptions provided to the model. To get the best results out of your model while using the Hydrolix MCP server, we recommend the following:
When running with HTTP or SSE transport, a health check endpoint is available at /health. This endpoint:
200 OK with the Hydrolix query-head's Clickhouse version if the server is healthy and can connect to Hydrolix503 Service Unavailable if the server cannot connect to the Hydrolix query-headExample:
The Hydrolix MCP server is configured using a standard MCP server entry. Consult your client's documentation for specific instructions on where to find or declare MCP servers. An example setup using Claude Desktop is documented below.
The recommended way to launch the Hydrolix MCP server is via the uv project manager, which will manage installing all other dependencies in an isolated environment.
The server supports multiple authentication methods with the following precedence (highest to lowest):
Authorization: Bearer <token> header?token=<token> query parameterHYDROLIX_TOKEN), orHYDROLIX_USER and HYDROLIX_PASSWORD)When multiple authentication methods are configured, the server will use the first available method in the precedence order above. Per-request authentication is only available when using HTTP or SSE transport modes.
Note: Using a service account token with a readonly role is recommended.
MCP Server definition using username and password (JSON):
MCP Server definition using service account token (JSON):
MCP Server definition using username and password (YAML):
MCP Server definition using service account token (YAML):
Open the Claude Desktop configuration file located at:
~/Library/Application Support/Claude/claude_desktop_config.json%APPDATA%/Claude/claude_desktop_config.jsonAdd a mcp-hydrolix server entry to the mcpServers config block to use username and password:
To leverage service account use the following config block:
Update the environment variable definitions to point to your Hydrolix cluster.
(Recommended) Locate the command entry for uvx and replace it with the absolute path to the uvx executable. This ensures that the correct version of uvx is used when starting the server. You can find this path using which uvx or where.exe uvx.
Restart Claude Desktop to apply the changes. If you are using Windows, ensure Claude is stopped completely by closing the client using the system tray icon.
To configure the Hydrolix MCP server for Claude Code, run the following command:
The following variables are used to configure the Hydrolix connection. These variables may be provided via the MCP config block (as shown above), a .env file, or traditional environment variables.
You MUST set one of the following to identify the cluster:
HYDROLIX_URL (recommended): The canonical public URL of your Hydrolix cluster, e.g. https://mycluster.hydrolix.live. For typical out-of-cluster deployments this single variable is sufficient — it supplies the host, port (scheme-default 443/80), and TLS settings for both the HTTP query endpoint and the REST /version probe.HYDROLIX_HOST (deprecated): The hostname of your Hydrolix server. Still honored for backwards compatibility but should be replaced by HYDROLIX_URL.When HYDROLIX_MCP_SERVER_TRANSPORT is http or sse, HYDROLIX_URL specifically is required (a forthcoming OAuth metadata endpoint would advertise it). HYDROLIX_HOST alone is not sufficient for these transports.
At least one authentication method must be configured when using the stdio transport:
HYDROLIX_TOKEN: Service account token for environment-based authenticationHYDROLIX_USER and HYDROLIX_PASSWORD: Username and password for environment-based authentication (both must be provided together)In summary:
If no credentials are provided via the environment or the request, the request will fail.
When using HTTP or SSE transport, you can omit environment-based credentials and instead provide authentication per-request. This is useful for multi-user scenarios or with clients that don't support running MCP servers locally.
Example mcpServers configuration connecting to a remote HTTP server with per-request authentication:
Example minimal .env configuration for running your own HTTP server without environment credentials:
Though not part of the MCP specification, many MCP clients allow adding headers to MCP-issued requests. When this is possible, we recommend configuring the MCP client to pass a service account token via the Authorization: Bearer <sa-token-here> header instead of as a query parameter for greater security.
Note: The bind host and port settings are only used when transport is set to "http" or "sse".
See docs/CONFIG.md for endpoint overrides, deprecated variable aliases, and the full set of optional tuning variables (timeouts, query SETTINGS overrides, result truncation, HTTP/SSE worker tuning, proxy, metrics, and escape hatches).
Tasks that need operational privileges — running the end-to-end suite against a
live Hydrolix cluster, and cutting a release — are documented separately in
MAINTAINERS.md.