# KiCad MCP Pro [Health: Active]

**Category:** 📐 Architecture & Design  
**Repository:** https://github.com/oaslananka/kicad-mcp  
**GitHub Stars:** 232  
**Views:** 12  
**Installs:** 0  
**Upvotes:** 0  
**Directory Page:** https://allmcps.com/mcp/kicad-mcp-pro

## Description
Production-grade MCP server for KiCad EDA—PCB design, DRC, simulation, BOM, DFM, and manufacturing.

## Tools
Capabilities this server exposes over MCP:

- **kicad_list_tool_categories** — List all available tool categories and capabilities. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **kicad_get_tools_in_category** — Get tool names in a category, optionally filtered by maturity.
- **kicad_set_project** — Set the active KiCad project directory and file paths. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **kicad_get_project_info** — Show the currently configured KiCad project paths. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **project_design_workflow** — Return the professional PCB design workflow as a typed phase state machine.

Lays out the canonical Planner -> Builder -> Verifier -> Fixer -> Release
sequence, with the high-level tool and the quality gates each phase must pass.
Pass the phases already finished in ``completed_phases``; the tool marks them
COMPLETE, reports the first remaining phase as READY (the current step) with
its next action and gates, and flags when a human gate is required. Read-only
and headless — use it to drive an autonomous design run step by step.
- **project_get_next_action** — Return the next high-priority action derived from the current project gate.
- **kicad_get_version** — Get KiCad version information and current connection status. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **pcb_get_board_summary** — Summarize the current board. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **pcb_visual_qa** — Headless PCB readability QA: off-board parts, silk and body overlap.

A fast, file-backed first pass that runs without a live KiCad: it flags
footprints whose body leaves the board outline, reference designators that
collide on the silkscreen, and overlapping footprint bodies — directly
from the ``.kicad_pcb`` geometry. It complements (does not replace) the
authoritative DRC run, which remains the sign-off check for courtyard and
silk clipping. Returns JSON with an overall PASS/INFO/WARN status and
per-finding refs/positions.
- **pcb_get_stackup** — Show the current stackup. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **pcb_get_design_rules** — Read the active board design rules file when available. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **sch_get_symbols** — List all schematic symbols, optionally from a child sheet. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **sch_get_bounding_boxes** — Return the estimated bounding box of every symbol in the active schematic.

Use this before calling sch_add_symbol or sch_build_circuit to understand
which areas of the schematic sheet are already occupied.  The bounding boxes
are heuristic estimates (KiCad does not expose exact extents via the file API)
but are conservative enough to avoid overlap in practice.

Returns:
    A table of all symbols with their centre position and estimated
    bounding-box corners (x_min, y_min, x_max, y_max) in mm, plus an
    occupied-area summary.
- **sch_get_connectivity_graph** — Summarize the active schematic as a textual net connectivity graph.
- **sch_visual_qa** — Run headless visual/readability QA on the active schematic sheet(s).

Detects readability defects ERC cannot — overlapping labels, off-sheet
symbols or labels, dense unreadable label fanout, and title-block gaps —
directly from the schematic S-expression geometry, with no rendering
required. Returns JSON with an overall PASS/WARN/FAIL status and per-sheet
findings carrying object refs and positions for follow-up.
- **lib_verify_component_contract** — Verify a placed component's symbol, footprint, and pins actually match.

For the given schematic reference designator this checks, entirely from
local project files (no network access):

- symbol pin count vs footprint connectable pad count
- pin numbers vs pad numbers
- footprint courtyard / fabrication / silkscreen completeness
- 3D model presence (advisory)
- datasheet evidence (advisory; never auto-filled)

Returns a JSON object with a ``status`` of PASS / WARN / FAIL and a list
of per-check ``findings``. FAIL marks a structural contract violation,
WARN marks a quality/completeness smell, and INFO is advisory evidence
that never changes the overall status.
- **lib_get_bom_with_pricing** — Generate a live BOM summary with unit and extended pricing.
- **run_erc** — Run schematic electrical rule checks. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **run_drc** — Return full DRC report with PCB violations, unconnected items, and courtyard issues.
- **validate_design** — Run DRC and ERC and summarize readiness. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **project_quality_gate** — Run the full project quality gate across schematic, PCB, DFM, and parity checks.
- **validate_footprints_vs_schematic** — Compare PCB footprint references against the schematic symbol references. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.
- **dfm_run_manufacturer_check** — Run a manufacturer-aware DFM review using the active bundled profile.
- **kicad_get_server_info** — Return versioned server information and capability diagnostics for clients. This KiCad MCP Pro tool supports production EDA automation workflows for MCP clients.

## Claude Desktop Quick Installation
Install path detected from listing signals. Uses `uvx` (confidence: high):

```json
"mcpServers": {
  "kicad-mcp-pro": {
    "command": "uvx",
    "args": ["kicad-mcp-pro"]
  }
}
```

## Documentation

## What KiCad MCP Pro does

KiCad MCP Pro connects an MCP client with KiCad EDA workflows for schematic review, PCB inspection, electrical and design-rule validation, design-for-manufacturing checks, BOM generation, and manufacturing handoff. It works with local project files and can report project paths, KiCad connection status, board structure, stackup, design rules, symbols, estimated schematic occupancy, and net connectivity.

The server also provides workflow coordination. A typed project state machine models the sequence Planner, Builder, Verifier, Fixer, and Release. Agents can provide completed phases to identify the next ready phase, its action, quality gates, and whether a human decision is required.

## How it works

The server communicates through MCP over either standard input/output or Streamable HTTP. Streamable HTTP serves the MCP endpoint at `/mcp` by default and can use a different mount path. The server can inspect KiCad files without a live KiCad process for several checks, including PCB visual QA and schematic readability QA.

PCB visual QA checks for footprints extending beyond the board outline, silkscreen reference collisions, and overlapping footprint bodies. Schematic visual QA checks geometry for overlapping labels, off-sheet objects, dense label fanout, and title-block gaps. These are first-pass checks; KiCad’s own DRC remains the authoritative sign-off check for relevant PCB violations.

## Setup and configuration

Install and launch the package with the CLI, for example:

```bash
uvx kicad-mcp-pro init
uvx kicad-mcp-pro tray
uvx kicad-mcp-pro dashboard --open
```

To expose MCP over Streamable HTTP, run:

```bash
uvx kicad-mcp-pro --transport streamable-http --host 127.0.0.1 --port 3334
```

A web dashboard can be opened at `http://127.0.0.1:3334/ui` with `uvx kicad-mcp-pro dashboard --host 127.0.0.1 --port 3334 --open`. The default profile starts with a bounded set of read-only review tools. Build mode with write access, release mode with manufacturing mode, and expert or full profiles are available for more trusted workflows.

## Tools and capabilities

- Discover tool categories and filter available tools by category or maturity.
- Set and inspect the active KiCad project and its file paths.
- Read board summaries, layer stackups, design rules, schematic symbols, estimated symbol bounding boxes, and connectivity graphs.
- Run PCB visual QA, schematic visual QA, DRC, ERC, combined design validation, and the project quality gate.
- Compare schematic references with PCB footprints and verify symbol, footprint, pad, courtyard, fabrication, silkscreen, model, and datasheet evidence for a component.
- Generate BOM summaries with unit and extended pricing, and run a manufacturer-aware DFM review using the active bundled profile.
- Inspect server capabilities, KiCad version information, connection status, and the next project action.

## Limitations and notes

KiCad MCP Pro is a first-pass design and review assistant, not an automated sign-off authority. Its signal-integrity, power-integrity, EMC, and thermal checks use first-order closed-form estimates and are not replacements for field solvers, EM or FEA simulation, or formal approval. DRC and the export pipeline use KiCad’s own engines.

PCB visual QA complements rather than replaces the authoritative DRC run. Schematic bounding boxes are heuristic estimates based on file geometry, so they help avoid overlap without representing exact KiCad-rendered extents. Live component sourcing uses the JLCPCB public catalog by default; Nexar, DigiKey, and Mouser require configured API credentials. Telemetry and error reporting are disabled by default.

_Full upstream README: https://allmcps.com/mcp/kicad-mcp-pro/readme_

