## Description
Governed OT data tap: 12 field protocols + cross-protocol RCA brain; audit + MOC gating.

## Claude Desktop Quick Installation
Install path detected from listing signals. Uses `uvx` (confidence: high):

```json
"mcpServers": {
  "industrial-aiops": {
    "command": "uvx",
    "args": ["iaiops"]
  }
}
```

## Documentation & README

<!-- mcp-name: io.github.industrial-aiops/iaiops -->

# Industrial-AIOps

**English** · [中文](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/README.zh-CN.md)

**Ask an AI agent why the line stopped — and get an answer that cites its evidence.**

A vendor-neutral, **read-first** data tap for the factory floor. It speaks **14 field protocols**,
correlates what it reads *across* them, and hands your agent an evidence-cited verdict instead of a
guess. Every call is audited, and no reading ever phones home.

```bash
pip install "iaiops[opcua]"      # pick your protocol — or [all]
iaiops init                      # write ~/.iaiops/config.yaml
iaiops doctor                    # check the setup before you trust it
```

Prefer a container? The published image is **cosign-signed** and runs **non-root**. It speaks MCP
over stdio, so keep stdin open and mount a volume for the audit store:

```bash
cosign verify --key deploy/margo/cosign.pub ghcr.io/industrial-aiops/iaiops:0.27.0-factory
docker run -i --rm -v iaiops-state:/home/iaiops/.iaiops \
  ghcr.io/industrial-aiops/iaiops:0.27.0-factory
```

For a hardened or air-gapped deployment (read-only rootfs, `cap_drop: ALL`, no-new-privileges,
optional on-box LLM) use [`deploy/margo/compose.yaml`](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/deploy/margo/compose.yaml) and
[`deploy/airgap/`](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/deploy/airgap/). The analysis engine needs **no GPU and no model API** — it is
deterministic; an LLM is optional and only *phrases* the verdict.

## What you get

|  |  |
|---|---|
| **Reads** | OPC-UA (+ Historical Access, tag auto-discovery) · Modbus TCP/RTU · S7comm · Mitsubishi MC · Omron FINS · MTConnect · MQTT/Sparkplug B · EtherNet/IP · EtherCAT · PROFINET · SECS/GEM · HART-IP · BACnet/IP · IO-Link — plus read-only REST layers for BAS supervisors (Metasys / Niagara) and Ignition Gateway |
| **Figures out** | downtime root cause (the flagship copilot), alarm floods (ISA-18.2), broken dataflows, data trustworthiness, OEE, asset inventory, legacy PLC program explainer (ST/AWL/L5X) |
| **Governs** | audit · budget · risk-tier · undo — on *every* call, through one engine, from both MCP and CLI |
| **Stays yours** | no telemetry, no phone-home. Six tools *can* send data off-box by design (`stream_publish`, `stream_publish_event`, `uns_publish`, `historian_push`, `mqtt_publish`, `rca_narrate`) — `IAIOPS_NO_EGRESS=1` withholds all six for an air-gapped posture |

Nine per-industry editions ship in this package — fab · factory · process · building · water ·
warehouse · clinical · renewables · plcnext — each adding its own read-only advisory checks.
Substation / utility telecontrol (IEC-104 · DNP3 · IEC-61850) ships separately as
[`iaiops-energy`](https://github.com/industrial-aiops/industrial-aiops-energy).

## Your first five minutes

Four commands. Only one of them touches a device, and it prints what it will send
before it sends anything.

```bash
pip install "iaiops[modbus]"     # pick the protocol you actually have, or [all]
iaiops onboard status            # ← run this first. Contacts NOTHING.
iaiops doctor                    # config, secrets, reachability — and the version
iaiops readiness                 # every scenario and what each gap needs
```

`onboard status` answers the smaller question you have first: **which of the six
steps is this site on, and what is the one command that advances it?** The six
were always there and nothing stated the order. It is derived from your store and
`config.yaml` every time, so there is no onboarding state to go stale — edit
`config.yaml` by hand and the answer stays true.

`readiness` reads your config and local store and answers one question: **which
scenarios can this site run today, and what does each gap need?** Every gap comes
with the command that closes it, ranked by how much it unlocks. No agent, no
cloud, no account, and nothing on the wire.

Then the path, in the order that matters — survey what is there, take a bounded
sample, and only then explain it:

| | | contacts a device? |
|---|---|---|
| **Survey** | `iaiops scan plan` → `iaiops scan run` | preview sends nothing; the run itemises every packet class it sent |
| **Configure** | `iaiops onboard draft` → you merge it into `config.yaml` | **no** — it reads the stored scan, and writes nothing |
| **Tap** | `iaiops collect run line1 --duration 7d` | yes — and it reports what it saw **and what it missed** |
| **Declare** | `iaiops tags export` → a person fills in `role` → `iaiops tags apply --by <you>` | **no** — the `role` column comes out empty on purpose |
| **Explain** | `iaiops oee measure --since … --until …` · `iaiops investigate open` · `iaiops diag rca` | **no** — all over collected history |

**See the whole thing run against a real device in about two minutes**, including
a genuine mid-run outage, with `./demo/oee-line/run_demo.sh` — no hardware, no
configuration, nothing written outside a temporary directory.
[demo/oee-line/](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/demo/oee-line/) explains what each step is for and what the
numbers do and do not claim.

## Why read-first

OT is exactly where you want an agent on a tight leash. The read paths are the product; the few
write paths are OT-dangerous, off by default, and gated by MOC discipline — dry-run, one-shot
approval, undo capture, hash-chained audit.

## Proving the analysis needs no model

The analysis layers cannot reach a language model. That is a guard, not a slogan:
`tests/test_brain_is_llm_free.py` scans eight packages — `brain`, `discovery`, `runtime`,
`readiness`, `collect`, `knowledge`, `retain`, `connectors` — for any import that could reach one,
and an empty result is the guarantee. A model is used in exactly two places, and neither is
load-bearing: `rca_narrate` rephrases a verdict that was already computed and already cited, and an
agent front-end decides *which* tool to call. Remove both and the numbers are the same numbers.

That guard is static — it proves nothing *can* call a model. For a validation team the sentence
they are asked to accept is the executed one, so it is executed:

```bash
iaiops verify determinism --out determinism-record.json
```

A pinned in-repo dataset goes through availability, production counts, the Six Big Losses,
ISA-18.2 alarm load, control charts, the conservative baseline and the RCA copilot. Each result is
canonically encoded and digested; the suite runs **twice in this process and once in each of two
fresh interpreters started at different `PYTHONHASHSEED` values** — the arm that catches a set or
dict iteration order reaching a result, which a single run never can. The socket API raises
throughout, so a computation that reached for a device or a hostname fails here instead of quietly
working on a machine that happened to be online. Afterwards the run is asked what it pulled in:
a model library that was *already* loaded (an MCP server holds `iaiops.core.llm` for the opt-in
narration tool) is recorded, not judged — only what the suite itself imported can condemn it.

The record separates `result` (identical every run — the part to sign) from `context` (when and
where this run happened). **Two good runs are not byte-identical records**, and someone will diff
them, so the halves are named rather than mixed.

This is the form the claim has to take to be usable: not "our model is accurate", which is not
evidence in a GxP context, but a test case someone can write into an IQ/OQ protocol — *remove the
model, block the network, re-run the standard dataset, compare the hash* — execute, and sign.
`verify_determinism` is the same check from the MCP side; `iaiops verify suite` lists what it
covers without running it.

## How far it's actually been verified

Short version: **verified against real protocol libraries, containers and in-process servers —
not yet against real plant gear.** We grade evidence rather than saying "tested", because a real
container round-trip and a synthetic fixture are not the same claim.

| Rung | What it means | Status |
|---|---|---|
| Real libraries / containers / in-process servers | OPC-UA (incl. cert `Sign`/`SignAndEncrypt` + A&C), Modbus-RTU over a `socat` PTY + `pymodbus`, BACnet/IP via `bacpypes3` on a two-IP subnet, **MTConnect against the Institute's own `cppagent`**, IoTDB / TDengine live write→read, HART codec vs `hart-protocol`, PLCnext route via `asyncua` | ✅ |
| Mock-verified (protocol logic exercised, no real device) | Omron FINS, IO-Link, BAS (Metasys / Niagara), Ignition Gateway, EtherNet/IP PCCC, Sparkplug B, S7 / MC / SECS-GEM | ⚠️ |
| **Real gear** | physical RS-485 devices, EtherCAT slaves, live HART gateways, live HVAC / BAS / Ignition, real PLCs | **zero, for every protocol** |

**Per-protocol evidence — including what each test does *not* cover — is in
[docs/VERIFICATION-RECORD.md](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/docs/VERIFICATION-RECORD.md)**, one row per protocol, naming the test
behind each claim. Every `待核实` is hardware-gated, not forgotten — each one names the equipment that would settle it.

## 🧪 测试与共创 / Beta testing & co-creation

**我们在找现场测试伙伴。** 软件里能验证的我们都验证了（真实 in-process 服务器、真实协议库、Docker 容器 loopback）——剩下的 `待核实` 清单只有真设备能回答：物理 Modbus-RTU（RS-485）、EtherCAT 从站、HART 网关、在线 BACnet 楼宇设备、在线 Metasys/Niagara BAS 控制器、在线 Ignition 网关、国产 PLC（汇川/信捷）、真机 PLCnext、真实变电站 RTU/IED、欧姆龙 FINS 真机、IO-Link 主站。如果你是 OT 工程师、系统集成商或工厂团队，手上有任何这类设备：装上 `iaiops`，对你的设备跑一遍 `iaiops doctor`，把结果告诉我们。**经你验证的设备会署名写进支持矩阵**；现场反馈的问题我们优先分诊；功能可以通过 GitHub Issues/Discussions 直接共创。

**We're looking for field-testing partners.** Everything software-verifiable has been verified; what's left on the honest `待核实` list only real equipment can answer — physical Modbus-RTU (RS-485), EtherCAT slaves, HART gateways, live BACnet HVAC, live Metasys/Niagara BAS controllers, live Ignition gateway, domestic PLCs (Inovance/Xinje), live PLCnext, substation RTUs/IEDs, live Omron FINS PLCs, IO-Link masters. If you're an OT engineer, integrator, or factory team with access to any of these: install `iaiops`, run `iaiops doctor` against your gear, and tell us what happened. **Verified-equipment reports get credited in the support matrix**, field-reported issues get fast triage, and features are co-designed in the open via GitHub Issues/Discussions.

👉 **参与入口 | Start here: [open an issue](https://github.com/industrial-aiops/industrial-aiops/issues/new) with the protocol and device model in the title, or email <zhouwei008@gmail.com>.** Either reaches a person, and a report gets answered against the current release.

---

## Consolidated capability matrix

| Protocol | Tool | Operation | R/W | risk_tier | Returns (key fields) |
|----------|------|-----------|:---:|:---------:|----------------------|
| OPC-UA | `opcua_server_info` | server status | R | low | state, product_name, namespaces |
| OPC-UA | `opcua_browse` | browse node tree | R | low | [{node_id, browse_name, depth}] |
| OPC-UA | `opcua_read_node` | read one node | R | low | value, datatype, source_timestamp, good |
| OPC-UA | `opcua_read_many` | batch read | R | low | [{node_id, value, ...}] |
| OPC-UA | `opcua_subscribe_sample` | bounded sample | R | low | {collected, samples[]} |
| OPC-UA | `opcua_read_alarms` | alarm surfacing | R | low | {active_alarms[], active_count} |
| OPC-UA | `opcua_read_history` | Historical Access (HDA) | R | low | {supported, count, values[]} |
| OPC-UA | `opcua_diagnose_connection` | connection triage | R | low | {verdict, checks[]} |
| OPC-UA | `opcua_discover_tags` | tag auto-discovery → semantic asset model | R | low | {tag_count, assets[], naming_report} |
| OPC-UA | `opcua_health_summary` | threshold classify (was `health_summary`¹) | R | low | {overall, counts, offenders[]} |
| OPC-UA | `opcua_anomaly_scan` | stddev outliers (was `anomaly_scan`¹) | R | low | {mean, stddev, outliers[]} |
| Modbus | `modbus_read_holding` | FC03 | R | low | {raw_registers, decoded[]} |
| Modbus | `modbus_read_input` | FC04 | R | low | {raw_registers, decoded[]} |
| Modbus | `modbus_read_coils` | FC01 | R | low | {bits[]} |
| Modbus | `modbus_read_discrete` | FC02 | R | low | {bits[]} |
| Modbus | `modbus_detect_byte_order` | byte/word-order auto-detect | R | low | {best_order, candidates[]} |
| Modbus | `modbus_list_templates` | vendor register templates | R | low | {templates[]} |
| Modbus | `modbus_apply_template` | decode block via template | R | low | {values:{name: engineering_value}} |
| Modbus | `modbus_health_summary` | threshold classify | R | low | {overall, counts, offenders[]} |
| S7comm | `s7_cpu_info` | CPU id + run/stop | R | low | {cpu_status, cpu_info} |
| S7comm | `s7_read_area` | read DB/M/I/Q | R | low | {items:[{address, value}]} |
| S7comm | `s7_read_db` | read data block | R | low | {items:[{address, value}]} |
| S7comm | `s7_read_many` | batch addresses | R | low | {items:[{address, value}]} |
| S7comm | `s7_write_db` | write data block | **W** | **high/MOC** | {before, written, _undo_id} |
| Mitsubishi MC | `mc_cpu_status` | CPU type | R | low | {cpu_type, cpu_code} |
| Mitsubishi MC | `mc_read_words` | word devices | R | low | {words[]} |
| Mitsubishi MC | `mc_read_bits` | bit devices | R | low | {bits[]} |
| Mitsubishi MC | `mc_read_many` | random read | R | low | {words[], dwords[]} |
| Mitsubishi MC | `mc_write_words` | write words | **W** | **high/MOC** | {before, written, _undo_id} |
| Omron FINS | `fins_cpu_info` | controller data read (0501) | R | low | {controller_model, controller_version} |
| Omron FINS | `fins_cpu_status` | controller status (0601) | R | low | {run_mode, status} |
| Omron FINS | `fins_read_words` | memory-area word read (DM/CIO/W/H/A/EM) | R | low | {words[]} |
| Omron FINS | `fins_read_bits` | memory-area bit read | R | low | {bits[]} |
| Omron FINS | `fins_read_many` | batch reads | R | low | {items[]} |
| Omron FINS | `fins_write_words` | memory-area write | **W** | **high/MOC** | {before, written, _undo_id} |
| MTConnect | `mtconnect_probe` | device model | R | low | {devices:[{components:[{data_items}]}]} |
| MTConnect | `mtconnect_current` | latest values | R | low | {observations[]} |
| MTConnect | `mtconnect_sample` | bounded stream | R | low | {observations[]} |
| MTConnect | `mtconnect_assets` | assets | R | low | {assets[]} |
| MTConnect | `mtconnect_oee_snapshot` | OEE inputs | R | low | {availability, execution, verdict} |
| MQTT/Sparkplug | `mqtt_read_topic` | bounded read | R | low | {messages:[{topic, payload}]} |
| MQTT/Sparkplug | `sparkplug_subscribe_sample` | bounded SpB sample (full decode) | R | low | {samples:[{sparkplug, payload:{metrics[]}}], seq_gap_count} |
| MQTT/Sparkplug | `sparkplug_decode_payload` | decode raw SpB payload | R | low | {metrics:[{name, alias, datatype, value, is_historical}]} |
| MQTT/Sparkplug | `sparkplug_node_list` | node discovery + state | R | low | {nodes:[{group_id, edge_node_id, online, devices}], primary_hosts[]} |
| MQTT/Sparkplug | `uns_browse` | topic-tree browse | R | low | {topics[], tree{}} |
| MQTT/Sparkplug | `uns_topic_audit` | UNS naming + sprawl governance | R | low | {verdict, sprawl_findings, findings{casing_collisions[], scattered_leaves[], …}} |
| MQTT/Sparkplug | `uns_schema_drift` | Sparkplug schema-drift (baseline vs current) | R | low | {verdict (none/additive/breaking), node_changes[]} |
| MQTT/Sparkplug | `uns_live_audit` | live UNS audit (bounded broker sample) | R | low | {verdict, findings{}} |
| MQTT/Sparkplug | `sparkplug_live_schema` | live NBIRTH schema snapshot | R | low | {nodes[], metrics[]} |
| MQTT/Sparkplug | `uns_live_drift` | live drift vs stored baseline | R | low | {verdict, node_changes[]} |
| MQTT/Sparkplug | `mqtt_publish` | publish/command | **W** | **high/MOC** | {published_bytes, applied} |
| EtherNet/IP | `eip_controller_info` | Logix controller id | R | low | {controller:{vendor, product_name, revision, serial}} |
| EtherNet/IP | `eip_list_tags` | tag discovery | R | low | {tag_count, tags:[{name, data_type, structure}]} |
| EtherNet/IP | `eip_read_tag` | read one tag/array | R | low | {tag, value, type, good} |
| EtherNet/IP | `eip_read_many` | batch read | R | low | {items:[{tag, value, type}]} |
| EtherNet/IP | `eip_write_tag` | write tag | **W** | **high/MOC** | {before, written, _undo_id} |
| Diagnostics | `diagnose_dataflow` | localize no-data | R | low | {verdict, diagnosis, hops[]} |
| Diagnostics | `alarm_bad_actors` | ISA-18.2 flood | R | low | {flood_verdict, top_offenders[]} |
| Diagnostics | `tag_health` | offender ranking | R | low | {overall, offenders[]} |
| Diagnostics | `historian_health` | gap/flatline | R | low | {verdict, gaps[]} |
| Diagnostics | `subscription_health` | sequenced-feed loss/reorder/overload | R | low | {verdict, missed_count, overloaded_channels[]} |
| Diagnostics | `downtime_root_cause` | AI downtime RCA copilot (cited, advisory) | R | low | {verdict, primary_cause, hypotheses:[{cause, confidence, evidence[]}]} |
| Diagnostics | `downtime_root_cause_live` | RCA copilot that gathers its own live evidence | R | low | {…downtime_root_cause…, collected_evidence} |
| Diagnostics | `learn_cause_weights` | learn per-site RCA cause weights from labeled incidents | R | low | {cause_weights{}, rationale} |
| Diagnostics | `data_quality_scorecard` | fleet data-trust rollup | R | low | {fleet_score, fleet_status, issue_breakdown, worst_tags[], endpoints[]} |
| Diagnostics | `data_quality_fleet_rollup` | cross-endpoint fleet view | R | low | {fleet_score, endpoints[]} |
| Diagnostics | `heartbeat_health` | heartbeat/watchdog liveness | R | low | {alive, distinct_transitions, longest_stall_s, reason} |
| Alarm (ISA-18.2) | `alarm_flood_analysis` | flood episodes / chattering / stale / summary | R | low | {episodes[], chattering[], stale[], summary{}} |
| Alarm (ISA-18.2) | `alarm_rationalization_worksheet` | CSV-exportable rationalization rows | R | low | {rows[], csv_path?} |
| Baseline | `baseline_learn` | conservative change-log baseline (refuses thin history) | R | low | {band{p1,p99,median,mad} \| insufficient_data} |
| Baseline | `baseline_check` | silent-by-default violation check | R | low | {status, violations[] (cited)} |
| Baseline | `baseline_record_change` | record operator change (restarts learning) | R | low | {recorded, change_point} |
| Baseline | `baseline_status` | no_baseline / learning / ok / violation | R | low | {status, window} |
| Historian | `historian_query` | read history back out of sqlite/TDengine/IoTDB | R | low | {rows[], truncated} |
| Historian | `historian_coverage` | per-tag row counts + first/last ts | R | low | {tags:[{tag, rows, first, last}]} |
| PLC program | `plc_program_outline` | structure of exported ST/AWL/L5X program | R | low | {blocks[], call_graph, timers[]} |
| PLC program | `plc_program_xref` | symbol/address cross-reference (cited lines) | R | low | {sites:[{kind, source_file, line, quote}]} |
| PLC program | `plc_program_section` | one named block's source (≤200 lines) | R | low | {text, source_file} |
| Export | `export_data` | export local store → CSV/SQLite/Parquet | R | low | {path, row_count, preview[]} |
| Analytics | `oee_compute` | OEE = A×P×Q | R | low | {availability, performance, quality, oee, oee_pct} |
| Analytics | `downtime_events` | stoppage detect + categorize | R | low | {event_count, total_downtime_s, by_category, events[]} |
| Analytics | `oee_multidim` | OEE machine×part×shift | R | low | {matrix[], worst_performers[], mean_oee} |
| Analytics | `asset_inventory` | active fingerprint | R | low | {assets:[{protocol, vendor, model, firmware, reachable}]} |
| Analytics | `cross_protocol_asset_model` | merge discovered tags into one asset model | R | low | {assets[], tag_count} |
| Analytics | `adopt_alias_map` / `diff_alias_map` | tag alias-map adopt/diff | R | low | {aliases{}, changes[]} |
| Analytics | `monitor_changes` | bounded change-of-value | R | low | {change_count, changes:[{value, previous, wall_clock}]} |
| EtherCAT | `ethercat_master_state` | master/WKC + slave count | R | low | {master_state, expected_working_counter, slaves_found, slaves_expected} |
| EtherCAT | `ethercat_slaves` | bus scan | R | low | {slave_count, slaves:[{index, name, vendor_id, product_code, state}]} |
| EtherCAT | `ethercat_slave_info` | slave detail | R | low | {sync_managers[], fmmus[], object_dictionary[], input_bytes} |
| EtherCAT | `ethercat_read_sdo` | CoE SDO upload | R | low | {index, byte_length, hex, as_uint} |
| EtherCAT | `ethercat_read_pdo` | input PDO snapshot | R | low | {working_counter, input_hex, input_byte_length} |
| EtherCAT | `ethercat_write_sdo` | CoE SDO download | **W** | **high/MOC** | {before, written, applied} |
| EtherCAT | `ethercat_set_state` | AL-state transition | **W** | **high/MOC** | {before, requested, reached, applied} |
| PROFINET | `profinet_discover` | DCP IdentifyAll (segment-wide) | R | low | {station_count, stations:[{name_of_station, mac, ip, vendor_id, device_roles[]}]} |
| PROFINET | `profinet_identify_station` | identify by name-of-station | R | low | {found, name_of_station, mac, ip, device_family} |
| PROFINET | `profinet_station_params` | targeted DCP Get (by MAC) | R | low | {found, name_of_station, ip, netmask, gateway} |
| PROFINET | `profinet_asset_inventory` | DCP asset register | R | low | {asset_count, io_controller_count, assets[]} |
| PROFINET | `profinet_dcp_set` | DCP Set (station name / IP suite) | **W** | **high/MOC** | {before, applied, _undo_id} |
| SECS/GEM | `secsgem_equipment_status` | GEM link + identity (S1F1/F2) | R | low | {communication_state, are_you_there} |
| SECS/GEM | `secsgem_list_status_variables` | SVID namelist (S1F11/F12) | R | low | {count, status_variables[]} |
| SECS/GEM | `secsgem_read_status_variables` | SVID values (S1F3/F4) | R | low | {svids, values[]} |
| SECS/GEM | `secsgem_list_equipment_constants` | ECID namelist (S2F29/F30) | R | low | {count, equipment_constants[]} |
| SECS/GEM | `secsgem_read_equipment_constants` | ECID values (S2F13/F14) | R | low | {ecids, values[]} |
| SECS/GEM | `secsgem_list_alarms` | alarm list (S5F5/F6) | R | low | {count, alarms[]} |
| SECS/GEM | `secsgem_list_process_programs` | PPID directory (S7F19/F20) | R | low | {count, process_programs[]} |
| BACnet (building) | `bacnet_discover` | Who-Is device discovery | R | low | {device_count, devices:[{device_id, address}]} |
| BACnet (building) | `bacnet_object_list` | a device's objects | R | low | {object_count, objects:[{object_type, instance}]} |
| BACnet (building) | `bacnet_read_property` | one object property | R | low | {object_type, instance, property, value} |
| BACnet (building) | `bacnet_read_points` | all present-values (HVAC snapshot) | R | low | {point_count, points:[{object_type, instance, present_value}]} |
| BACnet (building) | `bacnet_cov_subscribe` | bounded COV capture (always unsubscribes) | R | low | {notifications[], terminated_reason} |
| BACnet (building) | `bacnet_read_trend_log` | TrendLog readRange (bounded) | R | low | {records:[{timestamp, value}]} |
| BACnet (building) | `bacnet_write_property` | present-value write (priority) | **W** | **high/MOC** | {before, written, _undo_id} |
| HART-IP (process) | `hart_device_identity` | cmd 0 identity | R | low | {manufacturer, device_type, revision} |
| HART-IP (process) | `hart_primary_variable` | cmd 1 PV | R | low | {value, unit} |
| HART-IP (process) | `hart_dynamic_variables` | cmd 3 PV/SV/TV/QV + loop current | R | low | {variables[], loop_current} |
| HART-IP (process) | `hart_burst_sample` | bounded burst-variable sampling | R | low | {samples[]} |
| IO-Link | `iolink_master_info` | master identity | R | low | {vendor, product, serial} |
| IO-Link | `iolink_ports` | ≤32-port sweep (mode/status/device id) | R | low | {ports[]} |
| IO-Link | `iolink_device_info` | per-port device identity | R | low | {vendor_id, device_id, product_name} |
| IO-Link | `iolink_read_pdin` | process-data-in (raw hex + bytes) | R | low | {hex, bytes[]} |
| IO-Link | `iolink_read_isdu` | ISDU acyclic parameter read | R | low | {index, subindex, value} |
| IO-Link | `iolink_scan` | master + all connected devices | R | low | {master{}, devices[]} |
| BAS (Metasys/Niagara) | `bas_point_list` | supervisory point directory | R | low | {point_count, points:[{id, name, type}]} |
| BAS (Metasys/Niagara) | `bas_point_read` | read one supervisory point | R | low | {point, value, unit, status} |
| BAS (Metasys/Niagara) | `bas_alarm_list` | active controller alarms | R | low | {alarm_count, alarms:[{id, priority, state}]} |
| BAS (Metasys/Niagara) | `bas_trend_read` | trend/history samples (bounded) | R | low | {records:[{timestamp, value}]} |
| BAS (Metasys/Niagara) | `bas_command` | supervisory command (default-OFF; **life-safety object denylist** refuses fire/smoke/egress/pressurization before any I/O) | **W** | **high/MOC** | {before, written, _undo_id} |
| Ignition | `ignition_gateway_status` | Gateway + module health | R | low | {state, version, modules:[{name, state}]} |
| Ignition | `ignition_tag_browse` | tag-tree browse | R | low | {tags[], tree{}} |
| Ignition | `ignition_tag_read` | current tag values | R | low | {values:[{path, value, quality, timestamp}]} |
| Ignition | `ignition_alarm_status` | active alarms | R | low | {alarm_count, alarms:[{path, priority, state}]} |
| Ignition | `ignition_tag_history` | tag-history query (bounded) | R | low | {rows:[{path, timestamp, value}]} |
| 信创 / compliance | `compliance_mapping` | 《工控网络安全防护指南》↔ iaiops | R | low | {pillars[], status_summary, controls:[{pillar, status, gap}]} |
| 信创 / compliance | `compliance_frameworks` | 等保 2.0 + IEC 62443 FR1–6 crosswalk | R | low | {controls:[{crosswalk}]} |
| 信创 / compliance | `compliance_dengbao_levels` | 等保 二级 baseline vs 三级 增量 | R | low | {pillars:[{l2, l3_delta, status}]} |
| 信创 / compliance | `compliance_report` | deliverable compliance report (md/html) | R | low | {markdown \| out_path} |
| 信创 / compliance | `compliance_evidence_bundle` | audit-evidence zip (hash-chain verified) | R | low | {bundle_path, manifest} |
| 信创 / historian | `historian_push` | push telemetry to sqlite/TDengine/IoTDB | R(→historian) | low | {sink, received, written, skipped_non_numeric} |
| Self | `protocols_supported` | capability map | R | low | {protocols[], diagnostics[], analytics[]} |

*(The energy protocols — IEC-104 / DNP3 / IEC-61850 — moved to [`iaiops-energy`](https://github.com/industrial-aiops/industrial-aiops-energy) in 0.8.0; their tool matrix lives in that repo.)*

**196 governed tools** = 183 read + 10 MOC-gated **device** writes + `historian_push` (a write, to a historian rather than to a device: `[WRITE][risk=low]`) + the 2 deprecated aliases below. The device writes are (`s7_write_db`, `mc_write_words`, `fins_write_words`, `mqtt_publish`, `eip_write_tag`, `ethercat_write_sdo`, `ethercat_set_state`, `profinet_dcp_set`, `bacnet_write_property`, `bas_command`). The read side now includes two vendor-REST **read-only** layers above the field protocols — a **BAS controller layer** (Metasys/Niagara, building edition) and an **Ignition Gateway MES/SCADA** layer (factory edition). ¹ The 2 deprecated aliases are the two deprecated brain aliases `health_summary` / `anomaly_scan`, renamed to `opcua_health_summary` / `opcua_anomaly_scan` in 0.10.0 — the deprecated aliases are **still registered** and will be removed in a future release (target: 1.0.0). Read-only per-edition tools load ONLY under their edition (see *per-edition tool modules* below), so a bare protocol / single-edition surface is smaller than this line-wide total. The table above is representative, not exhaustive; run `protocols_supported()` (or `iaiops protocols`) for the live map.

---

## Per-protocol reference

### OPC-UA
- **Versions/variants**: binary `opc.tcp://` via `asyncua` (sync facade). Security: **anonymous + username/password**, plus **application-certificate message security (Sign / SignAndEncrypt)** — set `client_cert` + `client_key` (+ optional `server_cert`) and the client opens a signed/encrypted secure channel (no cert ⇒ the anonymous / username path is unchanged). **Validated end-to-end against an in-process asyncua server** (`tests/test_opcua_security.py`) for **Basic256Sha256** in **both Sign and SignAndEncrypt** modes: `server_cert` pinning *and* client-side server-cert auto-discovery are exercised, and the test asserts the negotiated policy URI + message-security mode on the live encrypted channel (plus a negative test that anonymous is refused by a secure-only server).
- **Connection params**: `endpoint_url`, `username` (password encrypted), `security_mode`, `security_policy`; for cert security `client_cert` / `client_key` / optional `server_cert` (PEM or DER paths; aliases `certfile` / `keyfile`).
- **Alarms & Conditions**: `opcua_alarm_events` — bounded event subscription + `ConditionRefresh`, events carry the server's own timestamps (verified against an in-process asyncua server; third-party A&C servers `待核实`). Untimed fallback: `opcua_read_alarms` browses alarm-like boolean nodes.
- **Not supported / planned** (`待核实`): cert-security interop with third-party / vendor servers (KEPServerEX / Prosys / Siemens / real PLCs), the other policies (Aes128Sha256RsaOaep / Aes256Sha256RsaPss / Basic128Rsa15 / Basic256), strict server-side certificate-trust enforcement, and cert-based *user* identity (X509 identity token, distinct from channel security).

### Modbus-TCP / Modbus-RTU
- **Versions/variants**: Modbus-TCP and **Modbus-RTU (serial RS-485/232)** via `pymodbus` (+ `pyserial`). Read function codes **FC01 (coils), FC02 (discrete), FC03 (holding), FC04 (input)**. Write FCs (**FC05/06/15/16**) = **not implemented** (read-only).
- **Connection params**: TCP — `host`, `port` (502), `unit_id`. RTU — `transport: rtu`, `serial_port` (e.g. `/dev/ttyUSB0`), `baudrate`, `unit_id`. Registers are untyped 16-bit words → `decode` hint (uint16/int16/uint32/int32/float32/raw); `modbus_detect_byte_order` auto-detects the byte/word order (AB/BA · ABCD/DCBA/BADC/CDAB) from hint values — pure logic, no extra device load.
- **Vendor register templates** (`modbus_list_templates` / `modbus_apply_template`): named register maps decoding a block into engineering values — energy meters (Eastron SDM630, Schneider PM5xxx, Carlo Gavazzi EM24), PV inverters (Huawei SUN2000, Growatt), Phoenix PLCnext process data, and water-industry templates (E+H Promag, Hach SC controller, generic dosing pump). Each template carries an explicit `待核实` caveat — no invented "verified" addresses.
- **Coverage**: many domestic 国产 PLCs (汇川 Inovance / 信捷 Xinje / 和利时 Hollysys / 台达 Delta) and any Modbus vendor. RTU framing is live-verified over a real serial link (socat PTY + pymodbus RTU server); specific physical RS-485 devices stay `待核实`.

### S7comm (Siemens + 仿西门子 国产)
- **Versions/variants**: `pyS7` (**pure-Python**, ISO-on-TCP / RFC1006 — no native `libsnap7`). **S7-300/400/1200/1500** and compatible clones. Memory areas **DB / M (merker) / I / Q**. No protocol auth (CPU gates via "Permit access with PUT/GET").
- **Connection params**: `host`, `port` (102), `rack`, `slot` (0/1 for 1200/1500; 0/2 common for 300/400).
- **Write**: `s7_write_db` = **high risk_tier, MOC, dry-run default**, captures BEFORE value + undo.
- **Not supported / planned**: optimized/symbolic DB access on 1500 with "optimized block access" can require absolute-addressing config on the CPU.

### Mitsubishi MC
- **Versions/variants**: `pymcprotocol` — **MC 3E frame (binary)** only. **1E / 4E frames = not supported.** PLC types **Q / L / QnA / iQ-R / iQ-L**. Devices: D/W/R (word), M/X/Y/B (bit).
- **Connection params**: `host`, `port` (5007 default; set to the module's open MC port), `plctype`.
- **Write**: `mc_write_words` = **high/MOC/dry-run default**, captures BEFORE + undo.

### Omron FINS (CS/CJ/CP/NX-via-FINS)
- **Versions/variants**: in-repo, **stdlib-only** FINS client (no third-party dependency — the `iaiops[fins]` extra pins nothing): 10-byte FINS header framing, **FINS/UDP** (default port 9600) and **FINS/TCP** (node-address handshake per Omron W342), SID matching, bounded response parsing, end-code table per W227/W342. Commands: 0101 memory-area read (words/bits over **DM/CIO/W/H/A/EM**), 0102 write, 0501 controller data read, 0601 controller status.
- **Connection params**: `host`, `port` (9600), `transport` (`udp` default / `tcp`), FINS network/node/unit addressing.
- **Write**: `fins_write_words` = **high/MOC/dry-run default**, captures BEFORE + undo; CLI double-confirm on `--apply`.
- **Validation**: verified against an in-repo mock FINS UDP/TCP responder (`tests/test_fins.py`); **live Omron PLC behaviour and banked-EM access stay `待核实`**.

### IO-Link (master JSON integration — read-only)
- **Versions/variants**: sensor-level visibility via the IO-Link **master's HTTP/JSON interface** (IO-Link consortium "JSON Integration"), both dialects selectable per endpoint via `flavor:` — `iotcore` (ifm IoT-Core POST envelope, default) and `rest` (plain-REST GET, Balluff/Turck-style). Reads: master identity, bounded ≤32-port sweep, per-port device identity, process-data-in (raw hex + bytes), ISDU acyclic parameter read. **NO write tools.** Bounded/size-capped HTTP (256 KiB response cap), schema-checked JSON with teaching errors. Reuses the MTConnect HTTP pin (`iaiops[iolink]` → `requests`).
- **Connection params**: master `host`/URL, `flavor`, `timeout_s`. `protocol: iolink`.
- **Validation**: in-process mock master in both flavors (`tests/test_iolink.py`); **live master datapoint paths stay `待核实`**.

### HART-IP (process instrumentation — read-only)
- **Versions/variants**: HART universal commands over **HART-IP UDP** (default, port 5094) or **TCP** (`transport: tcp`, length-delimited framing) via an in-tree transport; the HART command codec is verified vs `hart-protocol`. Tools: `hart_device_identity` (cmd 0), `hart_primary_variable` (cmd 1), `hart_dynamic_variables` (cmd 3, PV/SV/TV/QV + loop current), `hart_burst_sample` (bounded sampling of burst-published variables). **No write / device-specific commands exposed** (OT-dangerous on live instruments).
- **Connection params**: `host` (HART-IP server/gateway), `port` (5094), `transport` (udp default / tcp).
- **Validation**: TCP transport loopback-verified (in-process HART-IP server, real long-frame ACK through the real codec path); **live gateway behaviour and a true unsolicited burst subscription stay `待核实`**.

### MTConnect (ALL CNC machine tools)
- **Versions/variants**: agent **REST + XML** (`requests` + `xml.etree`), namespace-agnostic (parses MTConnect 1.x Devices/Streams/Assets schemas). Endpoints: `/probe`, `/current`, `/sample`, `/assets`. **Read-only by specification.** XML parsing is hardened (DTD/entity declarations rejected — XXE/billion-laughs defense).
- **Connection params**: `agent_url` (e.g. `http://host:5000`).
- **Not supported / planned**: MTConnect streaming (long-poll `interval=`); only bounded `count=` samples.

### MQTT / Sparkplug B / UNS
- **Versions/variants**: `paho-mqtt` — **MQTT 3.1.1 & 5**. Sparkplug B topic convention `spBv1.0/{group}/{type}/{edge}/[device]` (NBIRTH/DBIRTH/NDATA/DDATA/NDEATH/DDEATH/STATE). TLS + username/password supported.
- **Full Sparkplug B decode** (no optional extra): payloads are protobuf-decoded with a *vendored, byte-for-byte* copy of the official **Eclipse Tahu** `sparkplug_b.proto` generated module (depends only on `protobuf`). Per metric you get **name, alias** (resolved to its name via the BIRTH model), **datatype** (Int8…Int64/UInt…/Float/Double/Boolean/String/DateTime/Text/UUID/**DataSet**/Bytes/File/**Template**/PropertySet…), **value**, **timestamp**, and the **`is_historical` / `is_null`** flags. A **birth/death + seq model** tracks node/device **online** state (NBIRTH/DBIRTH ↔ NDEATH/DDEATH), builds the alias→name map from BIRTH, applies NDATA/DDATA by alias, and flags **`seq` gaps / out-of-order**. **Primary-host** awareness: `STATE/<host_id>` topics surface in `sparkplug_node_list`. `sparkplug_decode_payload` decodes a single raw payload (base64/hex) offline.
- **Connection params**: `host`/`broker`, `port` (1883 / 8883 TLS), `topic`, `use_tls`, `username` (password encrypted).
- **Command**: `mqtt_publish` = **high/MOC/dry-run default**. A *transient* publish has **no automatic inverse** (delivered is delivered); a **retained** one overwrites durable broker state, so it captures the prior retained payload and records an inverse.

### EtherNet/IP (Rockwell / Allen-Bradley)
- **Supported**: **ControlLogix / CompactLogix** (and GuardLogix) via **CIP / EtherNet-IP** using **`pycomm3`** (pure-Python — no native deps). **Tag-based**, symbolic access: read/write tags by name (`Conveyor.Speed`, `Array[3]`, `Program:Main.X`) and **discover the controller's tag list** at runtime (`eip_list_tags`, the headline feature). `eip_controller_info` reads the controller identity.
- **Connection params**: `host`, `slot` (0 for CompactLogix; the CPU slot for a ControlLogix chassis), `port` (44818). `protocol: ethernetip` (alias `eip`).
- **Write**: `eip_write_tag` = **high risk_tier, MOC, dry-run default**, captures BEFORE value + undo.
- **Not supported / planned**: **PLC-5 / SLC-500 (PCCC)** and **Micro800** are **not supported = roadmap** (Logix tag model only).

### EtherCAT (pysoem / SOEM fieldbus master)
- **Supported**: a **real EtherCAT master** via **`pysoem`** (the Python binding for the SOEM C stack). **CoE SDO read** (`ethercat_read_sdo`, acyclic mailbox upload) + **SDO write** (`ethercat_write_sdo`, download), **input PDO read** (`ethercat_read_pdo`, one bounded cyclic snapshot), **bus scan / slave enumeration** (`ethercat_slaves`, `ethercat_slave_info` — identity, SM/FMMU mapping, object-dictionary summary), **master/working-counter state** (`ethercat_master_state`), and **AL-state transitions** INIT↔PREOP↔SAFEOP↔OP (`ethercat_set_state`).
- **HARD REQUIREMENTS** (no way around them): **Linux**, **root or `CAP_NET_RAW`**, a **dedicated NIC** cabled to the bus, and **real EtherCAT slave hardware**. `pysoem` is an **OPTIONAL extra**: `pip install iaiops[ethercat]` — the base package installs and imports **without** it, and every EtherCAT tool then **degrades to a teaching error** (never crashes, never imports pysoem at module load).
- **NOT supported**: **no software simulator** exists (unlike OPC-UA / Modbus) — EtherCAT is **hardware-only** and **not testable in mock-only CI**; **macOS is unsupported**. **EoE / FoE / SoE** mailbox protocols and full PDO-mapping decode/expansion = **roadmap**.
- **Connection params**: `nic` (the dedicated interface name, e.g. `eth1`; alias `interface`), optional `expected_slaves` (a sanity check vs the bus scan). `protocol: ethercat`.
- **Operations matrix**:

  | Tool | Op | R/W | risk | Capture/notes |
  |------|----|:---:|:----:|---------------|
  | `ethercat_master_state` | master + WKC state, slave count | R | low | expected vs found |
  | `ethercat_slaves` | bus scan / enumerate | R | low | index/vendor/product/rev/addr/AL-state |
  | `ethercat_slave_info` | one-slave detail | R | low | SM/FMMU + OD summary |
  | `ethercat_read_sdo` | CoE SDO upload | R | low | hex + uint interpretation |
  | `ethercat_read_pdo` | input PDO snapshot | R | low | single cycle, never loops |
  | `ethercat_write_sdo` | CoE SDO download | **W** | **high/MOC** | before-value (SDO read-back) + undo |
  | `ethercat_set_state` | AL-state transition | **W** | **high/MOC** | before-state + undo; **can start/stop motion** |

- **Write/state safety**: `ethercat_write_sdo` (hex little-endian bytes) and `ethercat_set_state` are **high risk_tier, MOC, dry-run by default**, capture the BEFORE value/state for undo, and need a CLI double-confirm. **Changing EtherCAT state can START or STOP machine motion** — treat with extreme care. 未经授权勿对生产控制系统写入.

### PROFINET (DCP discovery / identify + gated DCP Set)
- **Supported**: layer-2 **PROFINET-DCP** via **`pnio-dcp`** — **`profinet_discover`** (DCP IdentifyAll: one broadcast surfaces *every* station on the segment — name-of-station, MAC, IP, vendor/device id, role — closer to passive discovery than a per-device fingerprint), **`profinet_identify_station`** (by name-of-station), **`profinet_station_params`** (targeted DCP Get by MAC → name + IP suite), and **`profinet_asset_inventory`** (a register with IO-controller vs IO-device role decoding).
- **Write**: **`profinet_dcp_set`** re-addresses one station (name-of-station and/or IP suite, by MAC) — **high risk_tier, MOC, dry-run default**, captures the BEFORE addressing + undo descriptor. Re-addressing a live station **can disrupt its IO connection**.
- **Scope (deliberate)**: **no RT cyclic process data** (that needs an IO-controller/IO-device stack and hard real-time — out of scope and unsafe to tap); the **blink / factory-reset** DCP services stay unexposed.
- **HARD REQUIREMENTS**: **raw-socket access** (root / admin / `CAP_NET_RAW`) on the **NIC on the PROFINET subnet**. `pnio-dcp` is an **OPTIONAL extra**: `pip install iaiops[profinet]` — the base package installs/imports **without** it, and every tool then **degrades to a teaching error**.
- **Connection params**: `host` — **THIS machine's IP** on the PROFINET subnet (the DCP broadcast goes out on it). `protocol: profinet`.
- **Preview caveat**: validated against a **mocked `pnio-dcp` DCP** — **not** verified against live PROFINET devices yet.

### Energy edition (electrical substation / utility telecontrol) → `iaiops-energy`
The energy vertical — **IEC 60870-5-104 / DNP3 / IEC 61850 MMS** read-only monitoring for substation RTUs/IEDs — **moved to its own package in 0.8.0**: [`iaiops-energy`](https://github.com/industrial-aiops/industrial-aiops-energy) (`pip install iaiops-energy`), built on `iaiops.core` (shared governance / brain / runtime). Its protocol reference, support matrix, and validation status live in that repo.

### Building edition (facility / HVAC / 厂务)
The **building** vertical adds **BACnet/IP** (ASHRAE 135) — the dominant building-automation protocol for HVAC, lighting, metering, and facility plant. Install with `pip install iaiops[building]` and expose with `IAIOPS_MCP=building` (bundle: bacnet + modbus + opcua + iolink).
- **BACnet/IP** (`BAC0` over bacpypes3): `bacnet_discover` (Who-Is device discovery), `bacnet_object_list` (a device's objects), `bacnet_read_property` (one object property), `bacnet_read_points` (present-value of all analog/binary/multistate points — the HVAC snapshot), `bacnet_cov_subscribe` (bounded change-of-value capture — capped by count AND wall-clock, always unsubscribes), `bacnet_read_trend_log` (TrendLog buffered records via one bounded readRange). Config: `host` = THIS machine's BACnet/IP interface (`ip` or `ip/mask`) / `port` (47808).
- **Write**: `bacnet_write_property` (present-value at a BACnet priority 1..16, or relinquish) = **high risk_tier, MOC, dry-run default**, BEFORE-value read-back + undo. Overriding a live building-control point **can move real HVAC/plant**.
- **Validation**: the **read path is verified** against a real bacpypes3 virtual BACnet/IP device through the actual async BAC0 stack (`tests/test_bacnet_live.py`); **COV / trend-log / writes on live HVAC gear stay `待核实`**.

### Water treatment edition (水处理)
`IAIOPS_MCP=water` (or `iaiops-mcp-water`, `pip install iaiops[water]`) exposes **modbus + opcua + hart** + the brain — the protocol set waterworks / wastewater plants actually run. Adds water-domain tag semantics (溶解氧 DO / ORP / 余氯 chlorine / 氨氮 ammonia / TSS/MLSS / 跨膜压差 TMP / UV / 加药 dosing / 曝气 aeration) and water-industry Modbus templates (E+H Promag, Hach SC controller, generic dosing pump — all with explicit `待核实` caveats).

### Warehouse / intralogistics edition (仓储 / 物料搬运)
`IAIOPS_MCP=warehouse` (or `iaiops-mcp-warehouse`, `pip install iaiops[warehouse]`) exposes **eip + profinet + modbus + opcua + sparkplug** + the brain — conveyor & sorter drives over EtherNet/IP (Rockwell) and Profinet (Siemens), VFD / energy meters over Modbus (`conveyor_vfd` / `agv_battery` templates), WMS/WCS gateways over OPC-UA, and AMR/IoT telemetry over MQTT-Sparkplug. Edition tools (read-only, advisory): `line_bottleneck` (Theory-of-Constraints throughput bottleneck across stations) + `sortation_health`. PdM (`pdm_forecast`), `downtime_triage` and OEE are reused as-is.

### Clinical-facility edition (医疗设施)
`IAIOPS_MCP=clinical` (or `iaiops-mcp-clinical`, `pip install iaiops[clinical]`) exposes **bacnet + modbus + opcua** + the brain — hospital facilities as a distinct patient-safety vertical over the building brain. Edition tools (read-only, advisory): `isolation_room_check` (负压/正压 isolation-room pressurization), `medical_gas_check` (medical-gas alarm-panel safety), `or_environment_check` (OR temperature / humidity / pressure envelope). BACnet BMS + Modbus gas-alarm panels + OPC-UA plant SCADA.

### Pharmaceutical-manufacturing edition (制药)
`IAIOPS_MCP=pharma` (or `iaiops-mcp-pharma`, `pip install iaiops[pharma]`) exposes **bacnet + modbus + hart + opcua** + the brain. **No new protocol** — that is the point: no field protocol is specific to pharma. Cleanrooms run BACnet, purified-water systems run Modbus and HART, filling and lyophilization run S7, DCS and bioreactors run OPC-UA, and all of it was already here. What pharma needed was *semantics*: the water edition's indicators are municipal (DO, ORP, chlorine, turbidity) and the clinical edition grades one room's pressure, where Annex 1 inspects the **cascade**.

Edition tools (read-only, advisory): `cleanroom_pressure_cascade` (EU GMP Annex 1, door by door — adjacency is **declared**, never inferred from a room list), `cleanroom_particle_check`, `pharma_water_check` (USP <645> stage-1 *procedure*: the non-temperature-compensated reading, the measured temperature rounded **down** to the tabulated step, and exceeding stage 1 reported as *proceed to Stage 2* rather than as a failure).

**No compendial limit tables are shipped.** The particle limits, the stage-1 conductivity table and the TOC limit belong to the site's qualified specification at its compendial revision. A transcription nobody in this repository can verify would end up deciding whether a batch environment passed — and the error that hurts is the flattering one, since a limit set too loose reads as "in specification". Limits are passed in and cited back; anything not declared is reported `no_limit` / `not_graded` and named, never counted as passing. Known gaps are listed in the edition's skill: no PI historian connector, S7 without hardware verification, no GxP (Annex 11 / Part 11) crosswalk yet, and LIMS / QMS deliberately out of scope — they run REST and databases, not field protocols.

### Renewables edition (光伏 / 风电)
`IAIOPS_MCP=renewables` (or `iaiops-mcp-renewables`, `pip install iaiops[renewables]`) exposes **modbus + opcua + sparkplug** + the brain — PV inverters (SUN2000 / Growatt templates) + wind-turbine controllers over Modbus, OPC-UA plant SCADA, and MQTT-Sparkplug telemetry. Edition tool (read-only, advisory): `pv_performance` (PV string performance vs expectation). Device-level monitoring + PdM via baseline / RCA.

### PLCnext packaging edition (Phoenix Contact vPLC)
`IAIOPS_MCP=plcnext` (or `iaiops-mcp-plcnext`, `pip install iaiops[plcnext]`) exposes **opcua + modbus** + the brain — the Phoenix Contact PLCnext virtualized PLC reached over its built-in OPC-UA server (`opc.tcp` 4840, `Arp.Plc.Eclr` address space) + Modbus-TCP process-data server; **no new connector**. Route-verified in-process; live PLCnext hardware reads stay `待核实` (see *How far it's actually been verified*).

### 信创 / China entry (offline · 国产 TSDB · compliance)
For 自主可控 / 信创 deployments — see **[docs/CHINA.md](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/docs/CHINA.md)** for the full guide.
- **Air-gapped install**: pure-Python core + per-protocol optional extras → install from a local wheelhouse with `pip install --no-index --find-links ./wheelhouse "iaiops[...]"`; secrets stay local (encrypted store), no cloud KMS.
- **National TSDB historian sink** (`historian_push`, CLI `iaiops historian push`): write collected telemetry to **TDengine** (`iaiops[tdengine]`) or **Apache IoTDB** (`iaiops[iotdb]`) — domestic, controllable; we don't build our own store or bind InfluxDB. *Data egress to the operator's own historian, not a control write.*
- **Compliance mapping** (`compliance_mapping`, CLI `iaiops compliance`): an honest 《工控系统网络安全防护指南》 ↔ iaiops self-assessment across 分区隔离 / 可审计 / 双向认证 / 最小权限 / 数据保护 / 自主可控, with per-control status (addressed / partial / 待核实) and the named gap.
- **国产 PLC**: 汇川 / 台达 / 信捷 over the existing **Modbus-TCP / S7** connectors.
- **⚠️ 待核实**: 国产 OS (麒麟/统信) · 芯 (鲲鹏/海光) · PLC validation and the TSDB write paths are documented but **not yet hardware-verified** — see the validation matrix in docs/CHINA.md.

### OEE / downtime analytics (cross-protocol, read-only)
- `oee_compute` — **OEE = Availability × Performance × Quality** from production inputs (planned time, run time, ideal cycle, total/good counts). Each factor is reported **raw + clamped to [0,1]**; a `capped` performance >1.0 flags an optimistic ideal cycle.
- `downtime_events` — auto-detects **running→stopped transitions** in a `{timestamp, state}` series and produces stoppage events with durations, **categorized** (changeover / material / mechanical / quality / break / unknown, by keyword heuristics or a `{state: category}` override).
- `oee_multidim` — aggregates OEE across **machine × part × shift** (or any dimensions) from labelled records → the matrix + worst performers.
- Operate over **provided/collected inputs** (fully testable without a plant). `mtconnect_oee_snapshot` surfaces the live MTConnect availability/execution inputs that feed these.

### Active asset inventory / fingerprint (read-only)
- `asset_inventory` — for each configured (or named) endpoint, **actively connects** with our own protocol client and reads its **identity** call (S7 `s7_cpu_info`, EtherNet/IP `eip_controller_info`, OPC-UA server build info, Modbus **Device Identification FC43/0x2B**, Mitsubishi CPU type, MTConnect device model), aggregating **vendor / model / firmware / serial / reachable / last_seen** into an asset register.
- **Honest scope (IEC 62443-flavored)**: this is **ACTIVE fingerprinting via our client connections**, **NOT** passive SPAN/tap discovery — it only finds devices we are configured to reach and adds light load to each. **Passive, traffic-mirroring discovery is roadmap.**

### OPC-UA Historical Access (HDA)
- `opcua_read_history` — reads stored historical values for a node over a `[start,end]` ISO-8601 window via the server's **HistoryRead** service (`asyncua` `read_raw_history`), **bounded** by `max_points` (≤2000). Returns `{supported:false, note}` **gracefully** when the server does not historize the node (no crash). Read-only.

### Change-of-value (CoV) monitor
- `monitor_changes` — bounded **deadband report**: polls a point and returns **only the value CHANGES** (with timestamps), not every sample. Works over **OPC-UA / Modbus / S7 / Mitsubishi MC / EtherNet-IP**. **Never an infinite loop** — hard-capped by both `duration_s` (≤120) and `max_changes` (≤500). Read-only.

### Cross-protocol brain — 0.9/0.10 additions (all read-only)
- **Conservative baseline learning** (`baseline_learn/check/record_change/status`, CLI `iaiops baseline …`) — a **change-log baseline, explicitly NOT black-box anomaly detection**: robust p1/p99 + median/MAD band over the local history, **refuses thin history** (<100 samples or <24h) with an explicit `insufficient_data` verdict, restarts at recorded operator changes, and is **silent by default** — a violation needs >3×MAD beyond the band AND ≥3 consecutive samples, and every violation cites its baseline window and offending samples.
- **Historian READ integration** (`historian_query` / `historian_coverage`, CLI `iaiops historian query|coverage`) — query history back out of the sqlite/TDengine/IoTDB sinks; an optional per-site `historian:` config block lets the RCA copilot pull the **2h pre-incident window** as one more cited evidence class (strictly additive — without the config, RCA output is byte-identical, test-proven).
- **Legacy PLC program explainer** (`plc_program_outline/xref/section`, CLI `iaiops program …`) — structural extraction over **exported** program files (Siemens SCL/ST `.scl`/`.st`, AWL/STL `.awl`, Rockwell Studio 5000 `.L5X` — never a live PLC upload); every element carries `source_file` + line (rung for L5X) so the explaining agent must cite real locations. XXE-hardened, ≤5 MB, extension allowlist.
- **ISA-18.2 alarm flood deep-dive** (`alarm_flood_analysis` / `alarm_rationalization_worksheet`, CLI `iaiops diag alarm-flood|alarm-worksheet`) — flood *episodes* (≥10 alarms/10 min), chattering, stale/standing (>24h), percent-time-in-flood vs target, and a CSV-exportable rationalization worksheet; over injected events or a live OPC-UA active-condition scan.
- **Open-format export + metrics bridge** — `iaiops export csv|sqlite|parquet` (from the local SQLite sink; Parquet via `iaiops[export]`) / MCP `export_data`; `iaiops metrics serve --port 9184` exposes Prometheus **`/metrics`** (latest tag values + counters, binds 127.0.0.1 by default) — Grafana recipe in `docs/GRAFANA.md`.
- **Compliance deliverables** — `iaiops compliance report` (等保 2.0 L2/L3 status + IEC 62443 FR1–6 crosswalk + honest gap list, md/html) and `iaiops compliance evidence` (audit-evidence zip with hash-chain verification + manifest); MCP `compliance_report` / `compliance_evidence_bundle`. Onboarding aids, 非认证.

### Cross-protocol brain & editions — 0.11/0.12 additions (all read-only)
- **Downtime triage copilot** (`downtime_triage`) — composes **alarm cascade + RCA verdict + PdM precursors** into one triage and cross-checks whether the first-out alarm agrees with the diagnosed cause; advisory, cite-first (builds on the earlier `alarm_cascade` first-out reconstruction and `pdm_forecast` time-to-threshold early-warning).
- **Legacy-PLC maintainability** (`plc_program_visibility`) — a risk/maintainability read over an **exported** ST/AWL/L5X program (size, block count, xref density, undocumented sections), never a live upload — pairs with the `plc_program_outline/xref/section` explainer.
- **Per-edition tool modules** (`EDITION_MODULES` in `mcp_server/profiles.py`) — a named edition can carry its own `@mcp.tool` group that loads **only when that edition is selected** — never for a bare protocol key and never in the always-on brain, so edition-specific tools stay off other surfaces and don't inflate the base. Every edition tool is **read-only, cite-first, advisory**:
  - **warehouse** — `line_bottleneck` (Theory-of-Constraints throughput bottleneck) + `sortation_health`
  - **clinical** — `isolation_room_check` (负压隔离病房 pressurization) + `medical_gas_check` + `or_environment_check`
  - **building** — `economizer_check` (AHU economizer FDD) + `zone_comfort`
  - **process** — `control_loop_health` (PID oscillation/offset/saturation) + `heat_exchanger_fouling`
  - **fab** — `spc_check` (SPC control-chart rules) + `defect_pareto`
  - **factory** — `changeover_analysis` (SMED)
  - **water** — `disinfection_ct` + `water_quality_compliance`
  - **renewables** — `pv_performance` (PV string performance)
- **Agent skills** — the repo ships a router skill (`skills/iaiops`) plus **ten** per-edition skills (`iaiops-fab` / `iaiops-factory` / `iaiops-process` / `iaiops-building` / `iaiops-water` / `iaiops-warehouse` / `iaiops-clinical` / `iaiops-pharma` / `iaiops-renewables` / `iaiops-plcnext`) that route an agent to the right MCP server and document the tool surface.

### Deployment & ecosystem fit (edge-native / Margo)
iaiops is designed to ride on a hardened, centrally-managed **edge host** as a portable, governed
**edge application** — not to own the host or the fleet manager. It maps naturally onto the
[Margo](https://margo.org/) edge-interoperability roles: the *host/device* is the immutable edge OS,
a *compliant orchestrator* places workloads by desired-state, and **iaiops is the OT-domain
application** — read-first tap + cross-protocol RCA, exposed as governed MCP tools, with an optional
**on-box LLM brain** for a fully air-gapped diagnostic path (data never leaves the plant).
> **Honest status:** iaiops is a natural Margo edge application but is **NOT Margo-compliant yet** —
> a container image + application description + a published conformance-toolkit result are roadmap
> `⏳` (see **[docs/MARGO-ALIGNMENT.md](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/docs/MARGO-ALIGNMENT.md)** and `docs/ROADMAP.md`). No material
> claims *Margo-compliant* until that test result exists.

A container + application-description **skeleton** lives in **[`deploy/margo/`](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/deploy/margo/)**
(hardened Dockerfile · compose · `待核实`-marked app descriptor); per-host distribution overlays
that reuse it live under **[`deploy/`](https://github.com/industrial-aiops/industrial-aiops/blob/HEAD/deploy/)** (one folder per candidate edge host).

---

## Install

Protocol client libraries are **optional extras** — install only the 1–2 protocols a site
actually runs (every protocol library is imported lazily; the base package installs and
imports without any of them, and a call to a not-installed protocol returns a teaching
error pointing at the right extra):

```bash
uv tool install "iaiops[opcua,modbus]"   # just the protocols you need
# or one per site:  pip install "iaiops[s7]"   ·   everything:  pip install "iaiops[all]"
# or a per-industry edition bundle:        pip install "iaiops[fab]"

iaiops init                 # interactive: add endpoints, store passwords encrypted
iaiops doctor               # config + per-protocol connectivity probe (point at simulators)
iaiops protocols            # the capability map
```

Protocol extras: `opcua` · `modbus` · `s7` · `mc` · `fins` (stdlib — pins nothing) · `eip` · `mtconnect` · `sparkplug` · `secsgem` · `ethercat` · `profinet` · `bacnet` · `hart` · `iolink` · `bas` (BAS supervisory REST — reuses the mtconnect HTTP pin) · `ignition` (Ignition Gateway read layer — reuses the mtconnect HTTP pin) · plus `tdengine` · `iotdb` · `influxdb` (historian sinks) · `nats` (stream egress) · `ollama` (on-box LLM narration) · `export` (Parquet) · `all` (every pip-installable connector).

> **Adapter belt** (`docs/ADAPTERS.md`): iaiops is a small neutral core (`ingress → normalize/govern/RCA → egress`) with pluggable, lazily-imported adapters — bind no store/bus/host/model, install only what a site runs. The RCA core is deterministic + cited, **not a black box** (`docs/RCA.md`); footprint is small by design (`docs/FOOTPRINT.md`).

**Edition bundles** (match the same-named `IAIOPS_MCP` profiles — install the protocols a vertical runs):
`fab` (secsgem + opcua + s7 + modbus) · `factory` (the discrete-manufacturing set: opcua + modbus + s7 + mc + fins + eip + mtconnect + sparkplug + ethercat + profinet + iolink + ignition) · `process` (opcua + modbus + hart) · `building` (bacnet + modbus + opcua + iolink + bas) · `water` (modbus + opcua + hart) · `warehouse` (仓储/物料搬运: eip + profinet + modbus + opcua + sparkplug) · `clinical` (医疗设施: bacnet + modbus + opcua) · `renewables` (光伏/风电: modbus + opcua + sparkplug — PV inverters (SUN2000/Growatt) + wind turbines + plant SCADA; device-level monitoring + PdM via baseline/RCA) · `plcnext` (opcua + modbus). The grid/substation energy bundle (IEC-104/DNP3/61850) ships in [`iaiops-energy`](https://github.com/industrial-aiops/industrial-aiops-energy).

### Master password
Secrets (per-endpoint passwords, MQTT credentials) are **never** stored in plaintext — they live in `~/.iaiops/secrets.enc` (Fernet + scrypt). Export `IAIOPS_MASTER_PASSWORD` so the MCP server/CLI can unlock non-interactively:
```bash
export IAIOPS_MASTER_PASSWORD='…'
```

### Example `~/.iaiops/config.yaml` (one block per protocol)
```yaml
endpoints:
  - name: line1
    protocol: opcua
    endpoint_url: opc.tcp://plc.lan:4840
    # username: operator           # password stored encrypted via init/secret set
    tags:
      - { ref: "ns=2;i=5", label: temp, warn_high: 70, alarm_high: 90 }
  - name: plc2
    protocol: modbus
    host: 10.0.0.5
    port: 502
    unit_id: 1
  - name: press1
    protocol: s7
    host: 10.0.0.6
    rack: 0
    slot: 1                        # S7-1200/1500
  - name: cell3
    protocol: mc
    host: 10.0.0.7
    port: 5007
    plctype: iQ-R
  - name: meter1
    protocol: modbus                 # Modbus-RTU (serial): set transport + serial_port
    transport: rtu
    serial_port: /dev/ttyUSB0
    baudrate: 9600
    unit_id: 1
  - name: omron1
    protocol: fins                   # Omron FINS (UDP default; transport: tcp for FINS/TCP)
    host: 10.0.0.11
    port: 9600
  - name: xmtr1
    protocol: hart                   # HART-IP gateway (read-only; udp default / transport: tcp)
    host: 10.0.0.20
  - name: iolm1
    protocol: iolink                 # IO-Link master JSON integration (read-only)
    host: 10.0.0.21
    flavor: iotcore                  # ifm IoT-Core (default) | rest (Balluff/Turck-style)
  - name: vmc1
    protocol: mtconnect
    agent_url: http://10.0.0.8:5000
  - name: uns
    protocol: mqtt
    host: broker.lan
    use_tls: true                  # → port 8883
    topic: spBv1.0/#
    # username: edge1              # password stored encrypted
  - name: cell5
    protocol: ethernetip           # alias: eip
    host: 10.0.0.9
    slot: 0                        # 0 for CompactLogix; CPU slot for ControlLogix
  - name: bus1
    protocol: ethercat             # Linux + root/CAP_NET_RAW + pip install iaiops[ethercat]
    nic: eth1                      # dedicated NIC cabled to the EtherCAT bus
    expected_slaves: 8             # optional sanity check vs the bus scan
```

### `iaiops init` walkthrough (per protocol)
```
$ iaiops init
Step 1 — master password: ********
Step 2 — add an endpoint
  Endpoint name (e.g. line1): press1
  Protocol ('opcua','modbus','s7','mc','mtconnect','mqtt') [opcua]: s7
  S7 PLC host (IP/FQDN): 10.0.0.6
  Port [102]: 102
  Rack (0 for S7-1200/1500) [0]: 0
  Slot (1 for S7-1200/1500, 2 for S7-300/400) [1]: 1
✓ Saved endpoint 'press1'.
```
(MQTT prompts add TLS/topic/username; MTConnect prompts for `agent_url`; EtherCAT prompts for the `nic` + `expected_slaves` and warns about the Linux/root/NIC/optional-extra requirement; OPC-UA/MQTT prompt for a hidden password stored encrypted.)

### Test against a simulator (per protocol)
- **OPC-UA** — an `asyncua` demo server (the test suite runs a real in-process one).
- **Modbus** — ModbusPal or a `pymodbus` server simulator.
- **S7** — a pyS7/snap7 S7 server sim (Snap7 server) on `:102`.
- **MTConnect** — the public MTConnect demo agent, or a local agent.
- **MQTT** — a local `mosquitto` broker (+ a Sparkplug edge for SpB topics).
- **Mitsubishi MC** — GX Simulator / an MC 3E server sim.
- **EtherNet/IP** — a pycomm3-compatible CIP/Logix simulator (or a spare CompactLogix).
- **Omron FINS** — the in-repo mock FINS UDP/TCP responder (`tests/test_fins.py`) or a spare CP/CJ PLC.
- **IO-Link** — the in-process mock master (`tests/test_iolink.py`, both JSON dialects) or any ifm/Balluff/Turck master on the bench.
- **EtherCAT** — **no simulator exists** (hard-real-time, raw-Ethernet). Validate only on **Linux**, as **root / with `CAP_NET_RAW`**, on a **dedicated NIC** wired to **real slaves** (e.g. a Beckhoff EK1100 coupler + EL terminals). `iaiops doctor` reports a clear "needs Linux/root/NIC/pysoem" status off the bus rather than failing.

---

## Usage

### Site survey — find what is on a network you have not been given a list for

Every other command needs an endpoint you already configured. `scan` answers the
question that comes first. It has no full-port mode, no raw sockets, no
half-open SYNs, and no write path of any kind; what it may touch is a fixed
industrial port allowlist, and how fast is capped by a ceiling the caller cannot
raise.

```bash
iaiops scan profiles                                   # what each posture does
iaiops scan plan --targets 10.0.0.0/24                 # sends NOTHING — the artifact you get signed
iaiops scan run  --targets 10.0.0.0/24 --site "Line 1" \
                 --approved-by "J. Controls" --ticket CHG-91 \
                 --report survey.html                  # scan → store → one HTML file
iaiops scan list                                       # stored surveys
iaiops scan report --out survey.html                   # re-render the latest
```

`scan plan` puts **nothing** on the wire. It prints every host and port that
would be touched, every class of packet that would be sent, the worst-case
duration, and the explicit list of what this tool never does — so you can run it
against a network before you have permission to scan it, and hand the output to
whoever grants that permission. `scan run` shows the same preview and asks once
before it sends anything (`--yes` to skip).

Postures run from `passive` (reads the local ARP cache, emits nothing at all) to
`legacy-safe` (reachability only, one host at a time, five connects a second —
for 1990s controllers where even a well-formed identify request is a risk).
`standard` and `deep` refuse to run without a recorded sign-off.

The HTML report is self-contained: no fonts, scripts, styles or images from
anywhere, and no network request when opened. Its **first** section is what the
scan touched — per-class emission counts, including requests that failed —
followed by the list of things it never does. The device table comes after that.

### From a survey to a measured OEE — the path the site actually walks

`scan` answers *what is out there*. These answer *what can I do with it, and what
is the number*. Each step is a real command; nothing here is a roadmap item.

```bash
iaiops readiness                                    # contacts NOTHING
```

What this installation can run **today**, and for each thing it cannot, the
specific input that is missing — ranked by how much supplying it would unlock. It
touches no device, so you can run it against a site you have not been authorised
to probe, which is the site that most needs the answer. It reports gaps; it never
fills one in (§9.4/D16 — a guessed production counter yields a plausible-looking
OEE, which is worse than an error).

```bash
iaiops collect plan line1 --duration 7d --interval-ms 1000   # contacts NOTHING
iaiops collect run  line1 --duration 7d --interval-ms 1000
iaiops collect run  line1 --duration 7d --resume             # after a closed lid
iaiops store status                                          # what the store holds
iaiops store prune --sealed-before 2026-08-01 --apply        # refuses without a seal
```

A **bounded** assessment run — capped at 14 days, and the operator must state the
end. There is deliberately no run-forever mode: a resident process on an OT
network needs change management, a laptop running for a week does not (D21). Every
run records the windows it could **not** see, so a gap is never silently readable
as a stoppage.

To get an OEE out of it, three tags have to be declared — which value means
running, which register counts parts, and (for Quality) which counts good ones:

```yaml
endpoints:
  - name: line1
    ideal_cycle_time_s: 0.1
    tags:
      - {ref: "0",  role: run_state,   running_when: [2]}   # 2 = running
      - {ref: "10", role: total_count}
      - {ref: "11", role: good_count}
```

`running_when` is **declared, never inferred**. On the `0=stopped 1=idle
2=running 3=fault` status word most PLCs expose, "any non-zero means running"
counts three states of four as production.

```bash
iaiops oee measure line1 --reported 97               # against the figure the site keeps
iaiops oee measure line1 --since 2026-03-02T06:00:00Z --until 2026-03-09T06:00:00Z
iaiops oee measure line1 --report oee.html --lang zh --site "一号厂区"
```

**Scope the measurement with `--since` / `--until`, together.** Without them the
period is everything the store holds for that endpoint — fine for one assessment
run, wrong the moment there are two: the idle weeks between a March run and an
August one become one enormous blind span and neither run can be measured.

The window is **charged for in full**. The parts of it that were never sampled —
before the first sample and after the last — count as blind exactly like a gap in
the middle, so narrowing the question to the minutes that happen to have data
cannot raise your coverage. Ask about a shift you observed two hours of, and the
answer is 25% coverage and a refusal, not "100% of what we saw".

Availability measured over the time the collector could **see**, with blind
windows excluded rather than counted as downtime; plus Performance, Quality and
the Six Big Losses. Each factor is reported only when its inputs were declared —
a partial OEE that names what is missing beats a whole one with a guess inside it.

`--report` writes **one self-contained HTML file** — no fonts, scripts, styles or
images from anywhere, and no network request when opened, so it works on an
air-gapped laptop and survives being forwarded as an attachment. Its **first**
section is what the measurement could see (coverage, blind time, sample cadence),
before the number, and it carries the row a sales deck usually leaves out: what
had to be declared to produce each figure, and what is still missing.

```bash
iaiops case open line1 --min-stop-s 300              # one case per long stoppage
iaiops case list                                     # each carries what someone DID after it
iaiops case causes                                   # the vocabulary a confirmation may use
iaiops case confirm <id> --cause material_starvation --by wei
iaiops case agreement                                # >90% agreement is a WARNING, not a score
iaiops diag learn-weights --site default             # learn a per-site cause profile
iaiops diag rca --input bundle.json --from-case <id> # a person's answer reaches the verdict
```

The label is a **by-product of work already being done**: the audit trail already
recorded that someone ran a write four minutes after the line stopped, so the
case shows it. Confirmation is one choice from a fixed vocabulary, never free
text, and a dismissal is a label too. Whether an answer counts as *independent* is
**derived** from whether the tool had suggested it — the answerer cannot claim it.

### The investigation itself — eight steps, and what each one needs

`readiness` answers *which scenarios this site can run*. This answers the next
question down: **if something stopped tomorrow, how far could we actually get?**

```bash
iaiops investigate plan                              # contacts NOTHING
```

Eight evidence steps — define the incident, collect the evidence, normalize and
check it, compress and rank, correlate the timeline, test the hypotheses, check
against known mechanisms, conclude and close. For each one it cannot walk, it
says whether that is something **you** have not supplied (with the command that
would) or something **this product** cannot express at all. Those two send a
person to very different places.

```bash
iaiops investigate open line1 --start <iso> --end <iso> --asset "Line 1"
iaiops investigate show <id>                         # the state it was left in
iaiops investigate list
```

The same eight steps over a **real past window**, persisted so it can be re-read
and advanced later. No device is contacted — the window is already over, and its
evidence is whatever was collected at the time.

Any of the three writes the forwardable version — one self-contained HTML file
that opens on an air-gapped laptop in a plant office:

```bash
iaiops investigate plan --report readiness.html --lang zh
iaiops investigate open line1 --start <iso> --end <iso> --report incident.html
```

Unlike `oee measure --report`, which **refuses** to write a file for a refused
measurement, this one writes for a blocked investigation on purpose. An OEE
report is a number, so a file existing at all claims one was measured. This
report's content is *how far this got and what each step still needs* — which
makes the blocked case the one most worth handing over, and for a site nobody has
instrumented yet it is the whole deliverable. What it will not do is let a
blocked investigation look finished: the headline is always the walk (`2 / 8`),
never a conclusion, and no step's own words appear above it.

### From a scan to a config

Everything on the path existed; nothing joined it. A site could scan forty
devices and then retype all forty by hand, and nothing anywhere said which of the
six commands came next.

```bash
iaiops onboard status                 # where am I, and what is the ONE next command
iaiops onboard draft                  # the newest scan → config.yaml endpoints
iaiops onboard draft --out draft.yaml # ...to a file you can review and merge
```

`draft` writes **nothing** into `config.yaml` — you merge it, exactly as with
`tags apply`. What it emits is constrained on purpose:

- **Only CONFIRMED protocols become endpoints.** An open 502 means something is
  listening, not that it is a Modbus device, and a config that said so would be
  believed. Those hosts are listed as skipped, with the reason.
- **Every value names the observation that justifies it** — and the interesting
  half is what the scan learned that you would otherwise have hunted for: the S7
  slot the CPU actually answered on, the MELSEC CPU's own `plctype`, whether an
  OPC-UA server advertises an unsecured endpoint or will need credentials.
- **A field the scan could not settle goes out commented**, saying what it is
  waiting for — never omitted. Omission lets the protocol default apply in
  silence, which is how a Modbus gateway gets read at unit 1 and shows a
  confident number for the wrong machine.
- **`tags:` comes out empty.** A scan finds devices; it establishes nothing about
  what their data means. That step is the next one, below.
- **Absence is not evidence.** The draft states what it structurally cannot
  contain — BACnet/FINS/HART are UDP and never swept; MQTT and the supervisory
  layers are never identified, by design.

`status` is derived from the store and `config.yaml` every time. There is no
onboarding state file, so a hand-edited config or a restored backup still gets a
true answer rather than a remembered one — and a step that is genuinely done
stays done even if you did the steps out of order.

For the point-list step it names the command **for your protocol**: `opcua
browse`, `eip tags`, `mtconnect probe`, `iolink ports`, `mqtt browse`, `bacnet
objects`, `ethercat slaves`, `hart dynamic`, or `modbus templates`. Where there
genuinely is nothing to ask — an S7 CPU exposes no symbol table on the wire, and
MELSEC and Omron memory carry none either — it says so **in that protocol's own
terms** and tells you where the addresses do come from, rather than one sentence
covering everything that is not OPC-UA.

### Confirming what the point list means

The one thing this product refuses to infer, and until now the only way to supply
it was hand-editing `role:` in a config file — which is exactly what stops working
at a hundred rows.

```bash
iaiops tags export sheet.csv          # every monitored tag; `role` column EMPTY
# a person fills in role + running_when
iaiops tags apply sheet.csv --by wei  # prints the exact config.yaml edit
```

The `role` column comes out **empty even next to a tag called
`GoodPartsCounter`**. A name is not a declaration; plenty of plants have one that
counts something else, and a wrong production counter yields a plausible OEE —
worse than an error (D16).

`apply` emits the patch rather than writing it. config.yaml stays the single
source of truth: `oee measure` reads roles off the config tag objects, so a
parallel store would let `readiness` call the mapping met while `oee measure`
still could not run. A `run_state` with no `running_when` is refused here, for
the same reason `MonitorTag` refuses it — "anything non-zero" counts idle and
fault as production.

Or tick it through in a page instead of a spreadsheet:

```bash
iaiops tags page confirm.html --lang zh
```

HLD §13.9's App front end, delivered as **a file rather than a served app**. A
localhost server inside an OT box has to answer which address it binds and who
authenticates — and since every declaration here requires `--by`, a page with no
identity cannot record *who* confirmed a tag, which is the one thing this step
exists to capture. So the page collects, and the author is supplied at `apply`.

The page **re-implements no refusal**. `run_state` needing `running_when`, a ref
having to be monitored, a role claimed twice — reproducing any of those in
JavaScript is how they drift from the ones that actually gate the config, and a
page that says "looks fine" while `apply` refuses is worse than no page. It ships
script (it is a form) but makes **no network request**: it works with the cable
out.

**There is deliberately no MCP tool for this.** An agent filling in the role
column is precisely the guess D16 exists to forbid.

Two of the steps need something a person has to state:

```bash
iaiops relations declare press oven --by wei         # which asset feeds which
iaiops relations downstream press                    # nearest first
```

The **second axis** of root-cause analysis. With time alone, an upstream stoppage
produces a string of equally-confident downstream false causes — on a line,
downstream co-occurrence is *guaranteed whatever the cause*. That guarantee is
why this is declared and not inferred (D25). Without it the timeline still runs;
it degrades to a single asset **and says so**.

```bash
iaiops knowledge mount mechanisms.yaml --by wei      # what is known about this equipment
iaiops knowledge check sensor_fault --protocol modbus
```

A fault-mechanism library, shaped by **ISO 14224**: the failure *mode* (what you
saw), the *mechanism* (what to go and check) and the *cause* (what to fix) stay
separate, because they answer different questions. Entries attach to the seven
taxonomy causes; they never add new ones — past roughly forty codes, two
operators stop picking the same one.

It may **exclude** and never **confirm**. A mechanism that cannot apply to this
equipment rules the candidate out, which is the strong move a ranker cannot make:

```
✗ sensor_fault — excluded
  every mounted mechanism for 'sensor_fault' applies only to hart, opcua — not to modbus
```

And a cause the library has never heard of reports **nothing known** — never "no
objection". A knowledge base that knows nothing about something has not cleared
it.

### Program change baseline — has the approved logic moved?

A control program is a controlled document, and the usual way an undocumented change to one gets
noticed is that somebody remembers. Record the version you consider approved, then ask a later
export whether anything moved:

```bash
iaiops program snapshot ~/exports/Line3.scl --name Line3 --label "approved v3.2 / MOC-118"
iaiops program drift    ~/exports/Line3_today.scl --name Line3
```

The snapshot stores the file's SHA-256 plus a per-block structural fingerprint — name/kind/language,
declared variables, calls, branch conditions, timers — and deliberately **excludes line numbers,
comments and block order**, so adding one comment at the top of a file does not report the whole
program as changed. What is stored on disk is block names, hashes and counts; never a declaration,
a source line or a comment, so the baseline store is not a second copy of your program.

Three verdicts, and each word is load-bearing:

| Verdict | Means |
|---|---|
| `identical` | The same SHA-256. Nothing else earns the word. |
| `logic_changed` | The extracted structure differs — reported per block, naming which of `variables` / `calls` / `branches` / `timers_counters` moved. |
| `changed_outside_extracted_structure` | The bytes differ and every block fingerprint matched. |

That third one is the honest one. It is *usually* comments or formatting — but these parsers extract
structure, they do not parse a grammar, so a real change inside a construct they do not model looks
identical from here. Calling it "documentation only" would be the comfortable reading of evidence
that does not support it, so it is not called that: line and comment counts are reported beside it
and the verdict still says look. **A drift report is a reason to read the diff, never a clearance.**

`iaiops program history` lists what is tracked; `iaiops program compare <name> <before> <after>`
diffs two stored snapshots. Deleting history is `iaiops program forget` and is **CLI-only** — an
agent should not be one call away from removing change-control evidence. Nothing is pruned
automatically. The name (not the path) is the identity, because the export directory changes every
time somebody opens the engineering station and the program does not; absent `--name` the file stem
is used and the output says so. No device is touched at any point — this reads a file a person
exported.

### CLI (read)
```bash
iaiops opcua read "ns=2;i=5" -e line1
iaiops modbus holding 0 -e plc2 --count 4 --decode float32
iaiops s7 read-db 1 REAL 4 -e press1 --count 2
iaiops mc words D100 -e cell3 --count 8
iaiops fins words 100 --area DM -e omron1 --count 8   # Omron FINS memory-area read
iaiops hart pv -e xmtr1                            # HART primary variable
iaiops iolink scan -e iolm1                        # IO-Link master + connected devices
iaiops mtconnect oee -e vmc1
iaiops mqtt nodes -e uns --timeout-s 15
iaiops eip tags -e cell5                           # Logix tag discovery
iaiops eip read "Conveyor.Speed" -e cell5
iaiops ethercat slaves -e bus1                     # EtherCAT bus scan (Linux+root)
iaiops ethercat read-sdo 0 4120 --subindex 1 -e bus1   # CoE SDO 0x1018:1
iaiops opcua history "ns=2;i=5" -e line1 --start 2026-06-28T08:00:00Z   # HDA
iaiops opcua monitor "ns=2;i=5" -e line1 --duration-s 20 --deadband 0.5 # CoV
iaiops diag dataflow -e line1 --ref "ns=2;i=5" --freshness-s 30
iaiops analytics oee 28800 25200 2.0 12000 11800   # OEE from five numbers you already have
                                                   # (for a measured one, see `oee measure` above)
iaiops analytics asset -e press1 -e cell5           # active asset register
```

### CLI (write — dry-run by default, double-confirm on `--apply`)
```bash
iaiops s7 write-db 1 INT 0 42 -e press1            # dry-run preview
iaiops s7 write-db 1 INT 0 42 -e press1 --apply    # double-confirm prompt
iaiops mqtt publish factory/line1/cmd '{"setpoint":50}' -e uns --apply
iaiops eip write-tag Setpoint 42 -e cell5 --apply  # Logix tag write (double-confirm)
iaiops fins write-words 100 42 --area DM -e omron1 --apply  # Omron FINS write (double-confirm)
iaiops ethercat write-sdo 0 24698 e8030000 -e bus1 --apply   # CoE SDO 0x607A download
iaiops ethercat set-state PREOP --slave 0 -e bus1 --apply     # AL-state (can stop motion!)
```

### MCP tool calls (JSON args → sample structured return)

`s7_read_db`:
```json
{ "db": 1, "dtype": "REAL", "start": 4, "endpoint": "press1", "count": 2 }
```
```json
{ "endpoint": "press1", "area": "DB", "db": 1, "dtype": "REAL", "start": 4,
  "count": 2, "items": [ {"address": "DB1,REAL4", "value": 20.5},
                         {"address": "DB1,REAL8", "value": 4.2} ] }
```

`s7_write_db` (dry-run):
```json
{ "db": 1, "dtype": "INT", "start": 0, "value": 42, "endpoint": "press1" }
```
```json
{ "address": "DB1,INT0", "dry_run": true, "before": 7, "would_write": 42,
  "note": "Dry run — nothing written. Re-run with dry_run=false AND a recorded approver…" }
```

`mtconnect_oee_snapshot`:
```json
{ "availability": "AVAILABLE", "execution": "ACTIVE", "controller_mode": "AUTOMATIC",
  "program": "O1234", "available": true, "running": true, "verdict": "running" }
```

`eip_read_tag`:
```json
{ "tag": "Conveyor.Speed", "endpoint": "cell5" }
```
```json
{ "endpoint": "cell5", "tag": "Conveyor.Speed", "value": 1500.0, "type": "REAL",
  "error": "", "good": true }
```

`eip_write_tag` (dry-run):
```json
{ "tag": "Setpoint", "value": 42, "endpoint": "cell5" }
```
```json
{ "endpoint": "cell5", "tag": "Setpoint", "dry_run": true, "before": 7,
  "would_write": 42, "note": "Dry run — nothing written. Re-run with dry_run=false AND a recorded approver…" }
```

`ethercat_read_sdo` (CoE SDO upload):
```json
{ "slave": 0, "index": 4120, "subindex": 1, "endpoint": "bus1" }
```
```json
{ "endpoint": "bus1", "slave": 0, "index": "0x1018", "subindex": 1,
  "byte_length": 4, "hex": "9a020000", "as_uint": 666 }
```

`ethercat_set_state` (dry-run; can start/stop motion):
```json
{ "state": "OP", "slave": 0, "endpoint": "bus1" }
```
```json
{ "endpoint": "bus1", "scope": "slave[0]", "dry_run": true, "before": "SAFEOP",
  "would_request": "OP", "note": "Dry run — no state change. … Changing EtherCAT state can start/stop machine motion." }
```

`sparkplug_decode_payload` (full SpB metric decode):
```json
{ "payload": "CAESBwoDYWJjEAE=", "encoding": "base64" }
```
```json
{ "encoding": "sparkplug_b", "seq": 0, "metric_count": 2, "historical_count": 0,
  "metrics": [ {"name": "Temperature", "alias": 1, "datatype": "Double", "value": 21.5,
                "is_historical": false, "is_null": false} ] }
```

`oee_compute`:
```json
{ "planned_time_s": 28800, "run_time_s": 25200, "ideal_cycle_time_s": 2.0,
  "total_count": 12000, "good_count": 11800 }
```
```json
{ "availability": {"raw": 0.875, "value": 0.875, "capped": false},
  "performance": {"value": 0.952381}, "quality": {"value": 0.983333},
  "oee": 0.819444, "oee_pct": 81.94 }
```

`asset_inventory` (active fingerprint):
```json
{ "endpoints": ["press1", "cell5"] }
```
```json
{ "asset_count": 2, "reachable_count": 2, "method": "active_fingerprint",
  "assets": [ {"endpoint": "press1", "protocol": "s7", "vendor": "Siemens/compatible",
               "model": "CPU 1511-1 PN", "firmware": "2.8", "reachable": true,
               "last_seen": "2026-06-28T10:00:00+00:00"} ] }
```

### Diagnostics (multi-dimensional JSON for an agent to visualize)

`diagnose_dataflow(endpoint="line1", ref="ns=2;i=5", freshness_threshold_s=30)`:
```json
{ "verdict": "comms_ok_value_stale",
  "diagnosis": "Connected with good status, but the value is STALE (age 412s > 30s) — the source/field upstream has stopped updating this point.",
  "recommended_action": "Trace upstream: the device serves the last value fine, so suspect the source/scanner/field signal that should refresh it.",
  "hops": [ {"hop":"connect","protocol":"opcua","ok":true,"detail":"OPC-UA state=0"},
            {"hop":"read_tag","ref":"ns=2;i=5","ok":true,"detail":"5.0"},
            {"hop":"freshness","evaluated":true,"stale":true,"age_seconds":412.0} ] }
```

`alarm_bad_actors(events=[…])`:
```json
{ "event_count": 55, "window_minutes": 0.82, "alarms_per_hour": 4024.4,
  "isa_18_2": {"ok_max":6,"manageable_max":12,"flood_min":30},
  "flood_verdict": "flood",
  "priority_distribution": {"high":50,"low":5},
  "pareto_sources_for_80pct": ["FIC101"],
  "top_offenders": [ {"source":"FIC101","count":50,"share_pct":90.9,"chattering":true,"standing":false} ],
  "chattering": ["FIC101"], "standing": [] }
```

`tag_health(tags=[…])`:
```json
{ "evaluated": 4, "overall": "alarm", "offender_count": 3,
  "offenders": [ {"ref":"hot","latest":99,"flags":["out_of_range_alarm"],"severity":3},
                 {"ref":"flat","latest":5,"flags":["flatline"],"severity":2},
                 {"ref":"bad","latest":null,"flags":["bad_quality"],"severity":3} ] }
```

#### AI downtime root-cause copilot (flagship)

`downtime_root_cause` correlates whatever evidence you can hand over — alarm
events, tag samples, a `diagnose_dataflow` verdict, a machine-state series —
around an incident window and returns an **evidence-cited, advisory** verdict.
Read-first: it proposes a human-approved, MOC-gated, undoable action and executes
nothing. Anti-hallucination by design — it cites only signals actually present in
the input, weights them by temporal proximity to onset (a cause precedes its
effect), and downgrades to `insufficient_evidence` (with a `recommended_next_data`
list) rather than guessing when evidence is thin.

`downtime_root_cause(window={"start":"2026-06-28T10:00:00Z","asset":"line1"},
alarms=[{"source":"M1_DRIVE","timestamp":"2026-06-28T09:59:52Z","message":"motor overload trip"}],
tags=[{"ref":"DRV1.Torque","samples":[10,11,99,99],"alarm_high":80}], dataflow={"verdict":"healthy"})`:
```json
{ "window": {"start":"2026-06-28 10:00:00+00:00","asset":"line1","duration_s":300.0},
  "verdict": "root_cause_identified",
  "primary_cause": {
    "cause": "mechanical_fault", "confidence": 0.722, "confidence_band": "high",
    "evidence": [
      {"signal":"alarm","ref":"M1_DRIVE","at":"2026-06-28 09:59:52+00:00","lead_time_s":8.0,
       "detail":"motor overload trip","weight":0.4959},
      {"signal":"tag","ref":"DRV1.Torque","detail":"flags=out_of_range_alarm severity=3","weight":0.45} ],
    "recommended_action": "Dispatch maintenance to inspect the faulting unit; if a latch/interlock is set, the reversible step is to clear the fault and reset the latch (MOC-approved, undo captures the prior latch state)." },
  "evidence_summary": {"alarms_supplied":1,"tags_supplied":1,"dataflow_verdict":"healthy","total_evidence_items":2},
  "anti_hallucination": "Advisory only — nothing is executed. Every cited signal is present in the supplied evidence …" }
```

The same copilot is on the CLI: `iaiops diag rca --input bundle.json` where the
bundle is `{window, alarms?, tags?, dataflow?, state_series?}`.

**Let it gather its own evidence.** `downtime_root_cause_live` (CLI `iaiops diag
rca-live`) takes just an endpoint + window + the refs to look at, then pulls the
evidence itself — a cross-protocol `diagnose_dataflow` probe, a short sampled
series per ref (so flatline / bad-quality / anomaly surface via `tag_health`),
and active OPC-UA conditions — before running the same advisory, read-only copilot.
The gathered bundle is echoed back under `collected_evidence` (no hidden inputs):

```bash
iaiops diag rca-live -e line1 --start 2026-06-28T10:00:00Z \
  --asset line1 --ref "ns=2;i=5" --ref "ns=2;i=6"
```

### Data-quality watchdog & UNS governance (read-only intelligence)
Two more pure-analysis layers — fully testable without live gear, and they feed the RCA copilot.
- **`data_quality_scorecard`** (CLI `iaiops diag dataquality`) — a fleet **data-TRUST** rollup: scores each tag 0-100 on whether its data can be *believed* — staleness, **dead heartbeat** (first-class), bad-quality, flatline, gaps, anomaly — then rolls up per endpoint and across the fleet with an issue breakdown and ranked worst offenders. Distinct from process health: it asks "can I trust this number," not "is this number alarming." `heartbeat_health` (CLI `iaiops diag heartbeat`) is the standalone watchdog-liveness check (a flatlined heartbeat = dead upstream even when comms look fine).
- **`uns_topic_audit`** (CLI `iaiops mqtt uns-audit`) — governs a UNS topic tree: naming conformance (allowed roots / min depth) + **topic sprawl** (casing collisions of the same logical name, leaf metrics scattered under many parents, depth outliers, duplicates) → a `clean`/`minor`/`sprawling` verdict. **`uns_schema_drift`** (CLI `iaiops mqtt uns-drift`) — compares two Sparkplug NBIRTH-style snapshots and classifies the change `none` / `additive` / `breaking` (a metric removed or its datatype changed). Positions the UNS as a *governable* neutral data source, not just a broker.

### MCP server
```bash
IAIOPS_MCP=opcua iaiops-mcp   # stdio transport (`iaiops mcp` is equivalent)
```

**Menu — expose only the protocols a site runs.** A fab usually runs 1–2 protocols;
exposing all 14 floods the model with tools it can't use. Set `IAIOPS_MCP` to a
comma-list of protocols and/or a named profile. **There is no default** (since
0.10.0): a bare `iaiops-mcp` prints the selection menu (profiles, protocol keys,
tool counts) to stderr and exits 2 instead of silently exposing 100+ tools. The
cross-protocol brain (OEE / downtime / diagnostics / asset / analysis) is included
by default with every selection.

```bash
IAIOPS_MCP=menu         iaiops-mcp   # print the menu (selections + tool counts)
IAIOPS_MCP=opcua,modbus iaiops-mcp   # two protocols + brain
IAIOPS_MCP=fab          iaiops-mcp   # named profile (secsgem+opcua+s7+modbus)
IAIOPS_MCP=opcua        iaiops-mcp   # effectively a single-protocol MCP
IAIOPS_MCP=all          iaiops-mcp   # everything — explicit opt-in only
                                     # (logs a tool-flood warning above 100 tools)
```

**Named entry-point sugar.** For the common single-protocol / single-edition case
there is a pre-scoped console script per protocol and per named profile — no env
var to set. Each is a thin shim over the same server:

```bash
iaiops-mcp-opcua     # == IAIOPS_MCP=opcua    iaiops-mcp
iaiops-mcp-modbus    # == IAIOPS_MCP=modbus   iaiops-mcp
iaiops-mcp-fab       # == IAIOPS_MCP=fab      iaiops-mcp  (per-edition)
iaiops-mcp-building  # == IAIOPS_MCP=building iaiops-mcp
iaiops-mcp-brain     # == IAIOPS_MCP=brain    iaiops-mcp  (brain only, 0 protocols)
```

**Multi-process sites — 1 brain MCP + N protocol MCPs.** Running several protocol
servers side by side (e.g. `iaiops-mcp-opcua` + `iaiops-mcp-modbus`) would duplicate
the ~30 brain tools in every server. Instead run one dedicated `iaiops-mcp-brain`
and set `IAIOPS_MCP_NO_BRAIN=1` on the protocol servers to strip the brain from
them — the `protocols_supported` discovery tool stays exposed everywhere:

```bash
iaiops-mcp-brain                          # the one cross-protocol brain server
IAIOPS_MCP_NO_BRAIN=1 iaiops-mcp-opcua    # lean protocol server, no brain
IAIOPS_MCP_NO_BRAIN=1 iaiops-mcp-modbus
```

**Write authorisation is not the tap's job.** iaiops does **not** withhold write
tools behind a server switch. Whether a write is allowed is the *caller's*
decision — the agent's judgement or account/permission management — and the tap's
job is to make that write **accurate, efficient, and un-bypassably audited**.
Every call, read or write, on **either** front-end (MCP tool *and* `iaiops` CLI),
goes through `@governed_tool` and leaves a row in `~/.iaiops/audit.db`. Writes are
additionally HIGH `risk_tier` and MOC-gated (dry-run + double confirmation + undo
capture + a recorded approver). `protocols_supported` reports this posture so the
model is *told* the rules rather than left to infer them.

Since **0.20.3** that promise is held by contract tests over the **real** tool
surface rather than by synthetic stand-ins: every one of the ten high-risk writes
is driven end to end and must be *denied without an approver with the connector
never reached* — "it raised" only proves an exception, not that nothing reached the
device. Two things those tests exposed on the way in: a call that **failed** was
audited as `ok` (tools return the canonical `{error, hint}` envelope rather than
raising, so the governance wrapper saw an ordinary return), which also told the
pattern circuit breaker "success" on every failure; and the runaway guard, blind to
a caller retrying a **denial** forever, let 500 identical denied writes through a
ceiling of 10. Both are fixed and pinned.

**Sealed sites — make the data-shipping tools cease to exist.**
`IAIOPS_NO_EGRESS=1` removes every tool whose job is to transmit local or plant
data to a destination the *caller* names, at registration time so a weak or
prompt-injected model cannot call what it cannot see:

```bash
IAIOPS_NO_EGRESS=1 iaiops-mcp-factory   # 134 tools -> 129; 5 withheld
```

Withheld: `stream_publish`, `stream_publish_event` (NATS message bus),
`uns_publish` (MQTT broker / Unified Namespace),
`historian_push` (external TSDB), `mqtt_publish` (broker), `rca_narrate` (POSTs
the RCA verdict — plant tags, values and citations — to a caller-supplied model
`base_url`). This is a **data-exfiltration / airgap** axis, not read/write
authorisation: `historian_push` is `risk_level="low"` — it changes no plant state
— yet it ships telemetry off-box, so this switch withholds it. It gates MCP tools
only, and is not a firewall (reads still open sockets to plant devices).
`protocols_supported` reports each posture independently.

Scope, stated plainly — this is **not a firewall**:

- It gates **MCP tools only**. `iaiops audit forward` (SIEM) is a CLI path no
  registry gate can reach; block it at the host if the box must be sealed.
- Reads still open outbound sockets. iaiops is a network tap — it must talk to
  PLCs, brokers and historians to read anything at all. The gate removes the
  tools whose *purpose* is sending data outward, not the network itself.
- It does not police arguments. A tool is present or absent as a whole; nothing
  is inspected at call time (that would be the call-time refusal this design
  rejects). This is why a tool with a caller-supplied destination is withheld
  even when its default points at localhost — the model picks the argument.
- Local file writes are **not** egress: `export_data` and
  `compliance_evidence_bundle` stay exposed. The bytes never leave the box;
  getting them off it afterwards is a host-level concern.
- **Both switches cover the `iaiops-mcp` server only** (including its
  per-protocol / per-edition entry-point shims). `iaiops-energy-mcp` is a
  separate server in a separate package and **does not honour them yet** — it
  mirrors in the base brain/compliance tools, so `IAIOPS_NO_EGRESS=1` there
  still leaves `historian_push`, `rca_narrate`, `stream_publish` and
  `stream_publish_event` exposed **on `iaiops-energy` 0.1.6 and earlier**.
  Fixed in `iaiops-energy` **0.1.7**, which pins `iaiops>=0.17` for exactly
  this reason. Said out loud because a switch believed to be on is worse than
  one known to be absent.

Named profiles: `all` · `brain` · `fab` · `factory` · `process` · `building` ·
`plcnext` · `water` · `renewables` · `warehouse` · `clinical`. In an MCP client (e.g. Claude Desktop) set `IAIOPS_MCP` per
server entry — or point the entry straight at the matching `iaiops-mcp-<name>`
script — one entry per site/line, each a lean single- or dual-protocol server.

---

## Safety & governance

- **Read-first.** 185 of the 196 tools are read-only, and `historian_push` writes to a historian rather than to a device. The 10 write/command tools (`s7_write_db`, `mc_write_words`, `fins_write_words`, `mqtt_publish`, `eip_write_tag`, `ethercat_write_sdo`, `ethercat_set_state`, `profinet_dcp_set`, `bacnet_write_property`, `bas_command`) are **OT-dangerous**: governed at **high risk_tier**, **off by default (dry-run)**, require a **double-confirm in the CLI**, and a recorded approver (one-shot `iaiops approve` tokens; with no `risk_tiers` configured, high/critical operations default to the `dual` tier) — **MOC discipline**. **All ten declare an undo** (no exemptions since 0.20.3); a successful write captures the BEFORE value/state and registers an inverse descriptor. The inverse honestly reports **"none"** where none exists — a *transient* (`retain=False`) `mqtt_publish` cannot be unsent, and `ethercat_set_state`'s `+ERR`/`NONE`/`BOOT` are not cleanly re-requestable AL-states. **An undo that over-promises is worse than none**, because someone will replay it onto live equipment. **`ethercat_set_state` can START or STOP machine motion.** 未经授权勿对生产控制系统写入.
- **Read/write authorisation is the caller's, not the tap's.** iaiops does not encode "this server may not write" by hiding tools — that decision belongs to the agent's judgement or account/permission management. The tap's guarantee is **un-bypassable audit on both front-ends**: every call, read or write, via an MCP tool **or** the `iaiops` CLI, runs through `@governed_tool` and leaves a row in `~/.iaiops/audit.db`. Writes are additionally high `risk_tier`, MOC-gated, and undo-captured (see above). High/critical calls **fail closed** when the audit DB cannot be written.
- **No-egress mode is enforced at registration.** `IAIOPS_NO_EGRESS=1` withholds the 6 tools that ship data off-box (`stream_publish`, `stream_publish_event`, `uns_publish`, `historian_push`, `mqtt_publish`, `rca_narrate`), fail-closed, for airgap/sealed-box deployments. This is a **data-exfiltration axis, not authorisation** — `historian_push` is low-risk (it changes nothing) yet pushes telemetry to an external TSDB, so this switch withholds it. Which tools count is derived from `@governed_tool(egress=True)` metadata and guarded by an AST scan in CI, so the *next* egress tool cannot silently escape the gate.
- **Do not point this at a production control system without authorization.** OT networks are safety-critical; even reads add load. Test against a simulator first.
- All endpoint-returned text is sanitized (prompt-injection defense); secrets are never returned by any tool; MTConnect XML is parsed with DTD/entity declarations refused.
- Every tool runs through the vendored governance harness: SQLite **audit** (`~/.iaiops/audit.db`, SHA-256 **hash-chained** rows + `iaiops audit verify`; audit **fails closed** for high/critical writes), token/call **budget** + runaway breaker, **risk-tier** gate (policy engine fails closed on a broken `rules.yaml`), **undo** recording. The MCP server **refuses to start** if any registered tool lacks the governance marker.

## Roadmap

Four items that used to sit here had in fact shipped — including two this same
README already listed as verified, three sections above. Listing built work as
future work is the same defect as claiming unbuilt work, so they are gone:
**EtherNet/IP PCCC (PLC-5/SLC-500) and Micro800**, **passive asset discovery**
(`iaiops scan --posture passive`, ARP-cache only, emits nothing),
**OPC-UA certificate security**, and **MTConnect streaming long-poll**.

What is genuinely open:

- EtherCAT **EoE / FoE / SoE** mailbox protocols and full PDO-mapping decode (CoE SDO/PDO read+write and AL-state landed in 0.3.0 via the optional `pysoem` extra).
- Sparkplug B **Template** deep expansion (DataSet landed in 0.17.0).
- **Contextual baselines** — one normal band per tag today, but an OT normal range moves with shift, product and start-up. Learn per bucket, and refuse a bucket with too few samples rather than falling back to a global band, which would disguise "never seen this regime" as "this regime is normal".
- **Relationship-aware root cause** — evidence is weighted by time only, so one upstream stoppage yields a run of equally-confident downstream false causes. A human-declared line order is enough to start.
- **Passive discovery from a SPAN/tap** — the ARP-cache posture is built; reading a mirror port is not.

**Missing a protocol, device, or feature? 缺功能提 issue/PR 欢迎留言** — open a [GitHub issue or PR](https://github.com/industrial-aiops/industrial-aiops/issues).