# copper-kicad-mcp [Health: Active]

**Category:** 📐 Architecture & Design  
**Repository:** https://github.com/claynicholson/copper-kicad-mcp  
**GitHub Stars:** 101  
**Views:** 0  
**Installs:** 0  
**Upvotes:** 0  
**Directory Page:** https://allmcps.com/mcp/copper-kicad-mcp

## Description
MCP server that lets any AI app design real, orderable KiCad boards: schematic, LCSC parts, PCB routing, ERC/DRC, JLCPCB fab files.

## Tools
Capabilities this server exposes over MCP:

- **copper_status** — Start here. Shows Copper + KiCad versions and installs, what works on this machine (kicad-cli, KiCad's pcbnew Python for
board edits, live IPC socket, Freerouting/Java for autorouting), the active project (+ whether it's open in KiCad, last ERC/DRC counts),
recent projects, tool modules that failed to load, `session` (what this session's Copper calls cost so far) and `next`: the single
most useful next call. detail='credits' returns the per-tool table instead: calls, result bytes, images, estimated tokens.
- **project_create** — Create a new KiCad project (.kicad_pro, .kicad_sch, .kicad_pcb) and make it active. Refuses to overwrite an existing
project. template: '2layer' (default) | '4layer' | 'blank' (KiCad defaults, no fab rules). fab: the fab profile whose
design rules the project gets (default: the configured one). board_size: [width_mm, height_mm] draws a rectangular
outline. dir: the parent folder (the project goes in dir/<name>), or the project folder itself when it ends in
<name>; default Documents/Copper/<name>. KiCad re-loads the files (ERC + DRC) before success is reported.
Example: project_create(name='usb-sensor', board_size=[50,30])
- **project_open** — Make an existing KiCad project the active one (all other tools then default to it). path: project folder,
.kicad_pro, .kicad_sch or .kicad_pcb. Returns a short overview + next steps (project_summary has the full digest).
A `project` argument on any other tool affects only that call; project_open is what changes the active project.
Example: project_open(path='C:/Users/me/Documents/KiCad/robot/robot.kicad_pro')
- **project_summary** — Compact digest of the active (or given) project: sheets, components by kind, ICs, nets, power rails, % of parts with a
part number (and which are missing one), missing footprints, board size/layers/tracks/vias/zones, the active parts providers + fab
profile (`config`), last ERC/DRC counts (and whether they are stale), and next steps.
Read-only and cheap; call it when you (re)start work on a design.
- **checkpoint** — Snapshot / list / diff / restore the project's design files (.kicad_sch, .kicad_pcb, .kicad_pro, rules, lib tables) in .copper/snapshots.
action: 'create' (label optional) · 'list' · 'diff' (id optional, default newest: what changed since) · 'restore' (id required;
snapshots the current state first, refuses if the file is open in KiCad). Mutating tools snapshot by themselves before they write.
Example: checkpoint(action='diff')
- **copper_help** — Worked examples, op catalogues and argument details for one Copper tool: the long-form help that is kept out of
the tool list. Call it before your first non-trivial use of a tool, or when a call came back BAD_ARGUMENT / BAD_OP.
Omit `tool` to list every tool with a one-line summary. Example: copper_help(tool='sch_apply')
- **sch_apply** — Edit the schematic with ONE atomic batch of ops (all succeed or nothing is written). Put a whole sub-circuit, or the
whole design, in a single call. Creates the .kicad_sch if missing. One call edits one sheet.
Pins are 'REF.PIN', PIN = number or name ('U1.PA9', 'J1.VBUS', 'R1.2'); a name on several pins connects them all.
Never compute coordinates: connect by NET NAME and Copper anchors the label or power symbol on the pin. New parts
take a temporary 'id' (one word) used in pins ('led.A'); the result's `refs` maps id to reference. Parts without
'at' are laid out automatically, and a sheet only Copper has arranged is re-drawn as titled functional blocks
(layout='keep' never does that; nothing is redrawn unless the netlist is proven identical).
ops (objects with "op"):
- place: lib_id | lcsc "C25804" | part (+provider) | spec "10k 0402" (resolved by the parts providers); id, ref, value, footprint,
  fields {LCSC:..}, near (ref/id), group mcu|power|connector|passive, at [x,y], rot, mirror, unit, dnp
- connect: pin | pins [..], net (power names like GND, +3V3, VBUS become power symbols; kind:'global' between sheets)
- power: pin(s), net · no_connect: pin | pins · pwr_flag: net · wire: from, to | points · label: net + pin | at
- set_field: ref, field, value | fields · move: ref, at | by, rot, mirror · swap: ref + lib_id | lcsc | part | footprint
- delete: ref | label | wire_at [x,y] | dangling:true · disconnect: pin(s) · rename_net: from, to · text: text, at
The result has what changed, the netlist check of every requested connection and KiCad's ERC with a ready `fix`
per issue, so a separate verify call is not needed.
Example: ops=[{"op":"place","lib_id":"Regulator_Linear:AMS1117-3.3","id":"ldo"},{"op":"place","spec":"10uF 0805","id":"cin"},
{"op":"connect","pins":["ldo.VI","cin.1"],"net":"VBUS"},{"op":"connect","pins":["ldo.GND","cin.2"],"net":"GND"}]
- **sch_read** — Read the schematic compactly: before editing an existing design, and to find exact pin names.
query: summary (default, counts) | components (ref, value, lib_id, footprint, LCSC, position) | pins (every pin of `ref`
with number, name, type and its net) | nets (net -> ['REF.PIN', ...], KiCad's full net names) | labels |
unconnected (pins ERC will flag, each with a ready fix). filter = case-insensitive substring.
Example: sch_read(query='pins', ref='U1') · sch_read(query='nets', filter='USB')
- **sch_tidy** — Re-draw a schematic sheet so it reads like a hand-drawn professional sheet WITHOUT changing the circuit: titled
functional blocks in signal-flow columns, canonical drawings per idiom (LDO, op-amp loop, crystal, LED chain), support
parts wired at the pin they serve, supplies up and grounds down, design notes, smallest paper that fits. Nothing is
written unless KiCad's netlist of the WHOLE project is identical before and after and ERC reports nothing new. A sheet
wired by hand is left alone (`style_used: 'kept'`) unless force=true; sheets with sheet symbols, buses or several
instances are refused. style 'pro2' (default); when the checks refuse it a simpler style is drawn: `style_used` says
which, `fallback` says why.
Example: sch_tidy() · sch_tidy(sheet='power.kicad_sch', dry_run=true) · sch_tidy(blocks=[{"id":"U2","title":"MCU"}])
- **library** — Search and inspect the KiCad symbol and footprint libraries this machine has (global + project tables): find a valid
lib_id / footprint before sch_apply place, and read exact pin names.
action: search_symbols (query = part number, name or keywords) | search_footprints (query; filters = footprint globs) |
symbol_info (lib_id -> pins with number, name, type, unit; default footprint) | footprint_info (fp_id -> pads,
courtyard, 3D model) | list (libraries in the active tables) | repair (fix "library not found": rebuilds missing or
stale global tables; dry_run defaults to TRUE).
Examples: library(action='search_symbols', query='USB C receptacle') · library(action='symbol_info', lib_id='Device:R')
- **parts_search** — Find parts. The project's parts providers are asked in order and the first with results answers (`provider` in the
result says which; 'local' = the user's own catalogue file, 'kicad' = generic library parts). Results are ranked by
spec match, then by the provider's part class (parts without a setup fee first), stock and price.
query: a value spec ('10k 0603', '100nF 16V 0402 X7R', 'LED red 0603', '12MHz crystal', 'LDO 3.3V SOT-223'), an MPN
('AMS1117-3.3') or a category phrase ('USB-C 16P', 'Header 1x4 2.54mm').
Each result: provider, id (the provider's part number), mpn, package, stock, price, match ('partial' = not every
term confirmed) and `next` = the exact sch_apply op. Passives by spec and known part numbers need no search:
sch_apply place resolves and imports them itself.
Example: parts_search(query='USB-C 16P', limit=5)
- **parts_get** — Full detail for one part by its provider part number. The provider is found from the id (a C-number is LCSC;
'name:id' names one) or `provider`.
lcsc: JLC **assembly** stock + Basic/Preferred/Extended class + price ladder + attrition (authoritative for JLC PCBA), LCSC **retail**
stock (a different pool — labelled), parameters, datasheet URL, whether EasyEDA has a symbol/footprint/3D model, and whether
parts_import would use a KiCad stock symbol+footprint or import from EasyEDA.
Other providers: the catalogue record (mpn, manufacturer, value, package, stock, symbol/footprint, extra supplier fields).
Use before committing to an unfamiliar part, or to check stock/class of a part already on the schematic.
Example: parts_get(part='C2040')
- **parts_import** — Make a provider's part usable in this project: returns the `lib_id` + `footprint` for sch_apply place. sch_apply
{"op":"place","part":...} calls this by itself; use it directly to inspect a part first or to force a source.
prefer='auto' (default) uses KiCad's stock symbol + footprint when it verifiably fits, else converts the provider's
symbol, footprint and 3D model into project libraries (registered in the project's lib tables); 'easyeda' forces the
provider's drawing, 'stock' fails if there is no stock fit. Footprint pads are checked against symbol pins and
KiCad itself loads the result. preview=true returns pictures of the symbol and footprint.
Example: parts_import(part='C165948')
- **parts_source_bom** — BOM sourcing pass: give every schematic component (all sheets) a part from the project's parts providers. Run it once
the schematic has values and footprints, before the fab pack. Per component it decides from an existing MPN field,
then value + footprint package, then an MPN in the footprint name; existing part numbers are kept (overwrite=true
re-picks) and checked against stock and package. Writes the provider's part-number field plus MPN / Manufacturer
(write=false reports only). Returns summary (sourced %, parts by class, setup-fee and cost estimates), `lines`
(decided), `manual` (could not decide: reason + options) and `stock_risks`.
Example: parts_source_bom(write=false) to preview, then parts_source_bom()
- **parts_alternatives** — In-stock substitutes for a part — use when a part is out of stock, in a dear assembly class (JLC Extended:
~$3 setup fee), or too expensive. target: a part number (→ same package, same value / same MPN family; for lcsc Basic > Preferred >
Extended, then stock) or a free-text spec ('100nF 0402'). For ICs the alternatives are the same MPN family from other
makers/packagings — check the datasheet pinout before swapping. Apply with sch_apply set_field (the result's `next` gives the op).
Example: parts_alternatives(target='C15401')
- **verify** — Run KiCad's own checks and get actionable findings. Use after EVERY batch of edits (sch_apply, pcb_*), and before fab_export.

what: list of 'erc' (schematic electrical rules), 'drc' (board rules + unrouted nets + schematic↔board parity; zones are refilled in memory,
the file is not modified) and 'review' (engineering heuristics, see design_review). Default: ['erc'] plus 'drc' when a board exists.
Each finding has severity, type, message, refs (pins like 'U1.3' / footprints), at [x,y] mm (on `sheet` for sub-sheets) and `fix` = the exact
next tool call, already pointed at the right sub-sheet. Repeats of one problem are merged into one entry with `count` + all `refs`.
`next` is the single most useful call to make now; `new` / `fixed` compare with the previous run. Checks run on the SAVED files.
Example: verify(what=['erc','drc'])
- **design_review** — Engineering review of the schematic netlist (and the board, if any): catches what passes ERC but kills boards.
Decoupling, I2C pull-ups, crystal load caps, USB-C CC resistors, USB ESD, regulator caps and feedback-divider voltage, floating EN/RESET/BOOT pins,
LED resistors, undriven rails, part sourcing (+ the fab's assembly-class fee), missing footprints, label typos, thin power-path tracks, thermal pads without vias.
Read-only. Each finding has a `fix`. checks: subset of the enum (default all but schematic_style).
Example: design_review(checks=['decoupling','usb_c_cc'])
- **render** — Look at the design: returns PNG image(s) the model can see. Use after edits to check layout, and with `crop` to zoom on a finding's `at`.

target: 'schematic' (every sheet, or `sheet`='name' for one), 'pcb' (2D layers), 'pcb3d' (raytraced 3D).
layers (pcb): default all copper + silkscreen + front mask + outline (no F.Fab: its value texts sit on top of the reference
designators); pass e.g. ['F.Cu','Edge.Cuts'] to choose. view: pcb → top|bottom; pcb3d → top|bottom|iso|iso_bottom|front.
crop: [x0,y0,x1,y1] in mm document coordinates (schematic / pcb top view). width: pixels, ≤ 2400 (default 1400).
Example: render(target='schematic', crop=[90,40,180,110])
- **pcb_read** — Read the PCB. With no arguments: a digest (footprint, track, via and unrouted counts, outline size, layers).
what: any of summary | footprints (ref, value, position mm, rotation, side) | nets | pads | tracks (every segment
with its uuid; combine with net) | widths (per-net copper summary) | zones | drawings.
refs: only these footprints. net: only that net. drc=true also runs KiCad DRC. source='live' reads the board open
in the running KiCad editor.
Example: pcb_read(what=["footprints"], refs=["U1"]) · pcb_read(what=["nets"], net="GND")
- **pcb_sync** — Update the PCB from the schematic (KiCad's "Update PCB from Schematic"); creates the .kicad_pcb if missing. Adds
missing footprints beside the outline, updates fields, swaps changed footprints in place, assigns every pad's net
and keeps existing positions. Copper follows renamed nets; copper left from deleted parts is reported.
remove_extra=true deletes footprints (and their orphaned copper) that are no longer in the schematic.
Refuses if the schematic has unannotated or duplicate references. board_build() runs this and the following steps.
Example: pcb_sync()
- **pcb_setup** — Board setup: outline, corner mounting holes, copper layer count, fab design rules + net classes, silkscreen text
size. Only what you pass is changed. Outline, one of: width x height mm rectangle (optional radius; REPLACES the
existing outline), polygon, auto_size=true (smallest comfortable rectangle for the parts, unrouted boards only), or
outline_file='case.step' (STEP, DXF, SVG, STL; 'auto' = the one file in mechanical/): the board body or an
enclosure's cavity with its arcs, cutouts and mounting holes; an uncertain pick lists candidates
(outline_pick), outline_dry_run=true only analyses. First setup applies the design rules of the
project's fab profile (rules='fab'). power_nets adds nets / patterns to the Power net class.
Examples: pcb_setup(width=40, height=30) · pcb_setup(width=50, height=50, radius=2, holes='M3', layers=4) ·
pcb_setup(outline_file='mechanical/case.step', outline_dry_run=true) · pcb_setup(power_nets=['VBAT','SW'], power_track=0.8)
- **pcb_place** — Place footprints. auto=true: connectivity-driven placement inside the outline (connectors on the edges, decoupling
caps at their IC pin, crystal at the MCU, RF antennas on an edge), courtyard-legal on a 0.5 mm grid; several
candidates are scored for elegance and the best is written. Locked parts and keep=[..] stay put; refs=[..] places
only those around what is there. On a routed board, placing everything is refused unless clear_tracks=true.
overhang={"J1": 1.2} lets a side-entry connector stick out past the edge.
moves=[{ref, x, y, rot, side, lock}]: exact positions in mm (board coordinates, as pcb_read), applied after auto
placement. Returns the ratsnest length before/after and the elegance score.
Examples: pcb_place(auto=true) · pcb_place(moves=[{"ref":"J1","x":101,"y":115,"rot":90}])
- **pcb_route** — Route the board. mode='auto' (default without tracks): autoroute every unrouted connection with Freerouting (Java and
the router are downloaded once into $COPPER_HOME/tools on first use). Existing tracks and vias are kept; a result
that is worse than before is reverted; the new tracks are then polished (polish=false skips that). Can take minutes
on dense boards. 2 layers: pcb_route(ignore_nets=["GND"]) then pcb_pour(net="GND", stitch=true). 4 layers: pour the
inner planes first.
tracks=[{"from":"U1.3","to":"C3.1","width":0.3,"layer":"F.Cu","waypoints":[[x,y]]}]: explicit connections; refuses to
join different nets or to cross other nets' copper.
pcb_route_guided is the built-in deterministic router (no download); board_build() picks for you.
Examples: pcb_route() · pcb_route(tracks=[{"from":"J1.1","to":"U1.3","width":0.5}])
- **pcb_pour** — Copper pour: a zone for one net (default GND) over the whole outline on the chosen layers (default F.Cu + B.Cu), then
fill every zone and re-run DRC. Pads the fill cannot reach get a solid connection or a via; what still cannot join
is reported with its position. stitch=true adds stitching vias. A pour on an inner layer is a plane.
Re-running replaces the net's zone; remove=true deletes it; fill_only=true just refills after moving or routing.
Examples: pcb_pour() · pcb_pour(net="GND", stitch=true) · pcb_pour(net="+3V3", layers=["In2.Cu"]) · pcb_pour(fill_only=true)
- **pcb_edit** — Low-level PCB escape hatch — a batch of ops applied in one transaction (all or nothing), then DRC:
  {"op":"add_track","points":[[x,y],[x,y],...],"width":0.25,"layer":"F.Cu","net":"GND"}
  {"op":"add_via","at":[x,y],"net":"GND","size":0.6,"drill":0.3}      (or "points":[[x,y],...])
  {"op":"delete","refs":["R7"]} | {"uuids":[...]} | {"nets":["SDA"]} (tracks+vias of those nets) |
      {"all_tracks":true} | {"zone_nets":["GND"]}
  {"op":"add_text","text":"v1.0","at":[x,y],"layer":"F.SilkS","size":1.0,"rot":0}
  {"op":"set_field","ref":"U1","field":"LCSC","value":"C12345","visible":false}
  {"op":"move","ref":"R1","x":110,"y":105,"rot":90,"side":"top"}    (locked part: add "unlock":true)
  {"op":"lock"|"unlock","refs":["J1"]}    (or "all":true)
Coordinates are mm (board coordinates as in pcb_read; track/via uuids from pcb_read(what=["tracks"])).
Deleting a footprint that is in the schematic only lasts until the next pcb_sync — delete the symbol instead.
Prefer pcb_place / pcb_route / pcb_pour when they fit.
- **pcb_route_plan** — Analyse the board for routing (read-only) and return what you need to write a plan for pcb_route_guided: board and
rules, a net table (kind, pads, unrouted, class), pours, keep-outs, a congestion map with hot spots, and
`suggested_plan` (the built-in heuristics as an editable plan) with `plan_schema`. Skip it to route with defaults.
heatmap=true attaches the congestion picture. ripup='all' analyses as if all unlocked tracks were removed.
Example: pcb_route_plan() -> edit suggested_plan -> pcb_route_guided(plan=...)
- **pcb_route_guided** — Built-in deterministic router (no download): same plan + same board gives the same copper; KiCad's DRC judges the
result and copper it rejects is removed again. No plan = built-in heuristics.
plan (all optional, mm, net globs ok): order [nets], global {grid, via_cost, style, layers, time_budget_s,
engine: "v2" (default) | "guided"},
nets {"<name>": {priority, width, layers, avoid:[[x0,y0,x1,y1]], corridor:[[x,y],..], max_vias, skip}},
diff_pairs [{p, n, gap, width}], regions [{rect, cost | forbid:true, layers, nets}]. Unknown fields are rejected.
ripup: none (default, keep existing tracks) | nets (re-route `nets`) | all. dry_run / compare never write.
Returns routed/total, failed [{net, from, to, reason, where, blocked_by}], per-net length and vias, DRC counts,
findings with fixes. A net with a pour only gets the pads the pour misses connected; ground without one is left
for pcb_pour. Routing nothing leaves the board untouched.
Examples: pcb_route_guided() · pcb_route_guided(ripup="all", plan={"order":["/USB_D?","*"]})
- **focus** — What the user is pointing at. Call it when they say "this part", "here", "that corner" instead of guessing.
action: get (default; the latest click / box in the Copper Canvas or selection in KiCad's PCB editor; wait=N waits up
to N s for their next one) | resolve (no human: what is inside box=[x0,y0,x1,y1] or nearest near=[x,y] mm on
document='schematic' | 'pcb') | open (start the Copper Canvas viewer and return its URL) | clear.
Returns focus {document, mode, box_mm | point_mm, refs, pins, nets, age_s}, items with value / footprint / position,
and a cropped PNG with the focus outlined. Empty refs with a box or point means the user means that AREA.
Use refs / pins in sch_apply, pcb_place, pcb_route; box_mm in render(crop=...).
Examples: focus() · focus(wait=60) · focus(action='resolve', document='pcb', box=[100,100,120,115])
- **fab_export** — Produce the order pack for a PCB fab: Gerbers + Excellon drill zipped, a BOM CSV and a placement (centroid/CPL) CSV,
all in the format of a fab PROFILE. Writes to <project>/copper-out/fab/.
profile: omit to use the project's configured profile (fab.profile in the Copper config; 'jlcpcb' out of the box). Built in:
'jlcpcb' (Protel gerbers; BOM 'Comment, Designator, Footprint, LCSC Part #'; CPL 'Designator, Mid X, Mid Y, Layer, Rotation' with
JLC rotation corrections), 'pcbway', 'oshpark' (bare boards) and 'generic' (Gerber X2 + Excellon + KiCad position file + plain BOM
with MPN/Manufacturer — for any other fab). Users add their own as JSON in $COPPER_HOME/fabs/ or <project>/.copper/fabs/.
profile='list' returns every available profile with its rules and notes (nothing is exported).

It first runs ERC + DRC (zones refilled, schematic parity) and REFUSES (error FAB_BLOCKED, listing blockers with fixes) for whatever
the profile says blocks an order: ERC errors, DRC errors, unrouted nets, parity issues, no board outline, an empty board and — for
profiles that need one per part, like jlcpcb — assembled parts without the profile's part number.
Fix the blockers (each comes with the next tool call); pass waive=[codes] ONLY for things the user consciously accepts:
'erc','drc','unrouted','parity','parts','outline','empty' or 'all'. assembly=false skips BOM + placement (bare PCB order).
With assembly it also asks the parts provider for live stock of every BOM part (for `boards` boards, default 5): parts with zero /
too little stock or not listed come back in `warnings` (code 'stock': affected refs + a ready parts_alternatives fix per part). That never blocks;
waive=['stock'] acknowledges it. Offline (or with check_stock=false), `stock.not_checked` and the first order note say stock was NOT checked.
Every output is checked (non-empty, complete layer set, zip readable). Returns board size, layers, min track/drill, part counts,
`summary.assembly_fees` (Basic / Preferred / Extended counts, the fee total, `extended_refs` = which parts cause it) when the
profile has part classes, and order notes.
Examples: fab_export() · fab_export(profile='generic') · fab_export(waive=['parts']) · fab_export(assembly=false)
- **export** — Export any other manufacturing/documentation output with kicad-cli; the files are verified to exist and be non-empty.
kind: pdf_schematic | svg (schematic, one per sheet) | pcb_pdf | step | glb | vrml | ipc2581 (BOM columns from the part-number/MPN fields) | odb |
netlist (KiCad s-expr) | bom (CSV grouped by Value/Footprint/part number) | pos (CSV, mm, both sides, DNP excluded) | drill | gerbers | render3d (PNG) |
stats (board statistics JSON) | ipcd356.
out: file (or folder for svg/drill/gerbers); default <project>/copper-out/export/. For a fab's order pack use fab_export instead.
Examples: export(kind='step') · export(kind='pdf_schematic') · export(kind='pcb_pdf', layers=['F.Cu','Edge.Cuts'])
- **board_build** — The whole board in ONE call: update the PCB from the schematic, outline, placement, routing, ground pour and
KiCad's DRC + ERC, with one compact report (a line per stage, error groups with fixes, `fab_ready`, `next`). Use it
instead of pcb_sync, pcb_setup, pcb_place, pcb_route, pcb_pour and verify one after another.
width/height (mm) apply when the board has no outline (omit both to size it from the parts) or with
outline='replace'. An existing outline, existing tracks and placed parts are kept: on a board that already has
copper only new footprints are placed and only missing connections are routed.
If the result has `pending`, the time box was reached: call board_build() again to continue.
Example: board_build(width=50, height=32)

## Claude Desktop Quick Installation
Install path detected from listing signals. Uses `npx` (confidence: high):

```json
"mcpServers": {
  "copper-kicad-mcp": {
    "command": "npx",
    "args": ["-y","copper-kicad"]
  }
}
```

## Documentation

## What copper-kicad-mcp does

copper-kicad-mcp gives an MCP-compatible AI application access to a KiCad-based electronics design workflow. It can turn a request such as a USB-C ESP32-C3 board specification into connected schematic nets, selected components, a PCB layout, validation results, visual renders, and manufacturing files.

The workflow uses named pins and nets rather than coordinate-based connections. Parts can be found through LCSC and JLCPCB searches, with symbols, footprints, and available EasyEDA 3D models imported into the project. Fabrication output includes Gerbers, drill data, a bill of materials, and placement files.

## How it works

The package runs on the user's machine and connects to a locally installed KiCad 10 installation. An AI application invokes Copper's MCP tools; the model itself remains part of that AI application, because Copper does not make language-model calls.

After design changes, KiCad's electrical rules check and design rules check can be run again. The workflow also supports component placement, PCB routing, copper pours, differential pairs, length matching, width classes, and Freerouting. Schematic, board-layer, and ray-traced 3D renders can be returned to the model for inspection.

Copper accesses the internet for component searches and downloads, update checks during setup or diagnosis, and optional autorouting dependencies. Designs remain on the local machine, and the project reports no telemetry.

## Setup and configuration

KiCad 10 is required. For Node-based installation, run:

```sh
npx -y copper-kicad setup
```

This route requires Node.js 18 or newer. The setup process locates KiCad, carries over libraries and settings, connects configured AI applications, and performs a test call. It asks for confirmation before each step and backs up changes. A demonstration mode is available with `npx -y copper-kicad setup --demo`, while `npx -y copper-kicad doctor` helps identify setup fixes.

Windows users can install through the Copper setup executable or the PowerShell installer. macOS and Linux provide a shell installer. Claude Desktop can use the downloadable MCP bundle, and Claude Code can be installed through its marketplace and plugin commands. Cursor, VS Code, Windsurf, Codex, and Zed can use the `npx` setup route or an MCP configuration containing the `copper-kicad` command.

The optional `COPPER_NO_UPDATE_CHECK=1` setting disables KiCad update checks performed by `setup` and `doctor`.

## Tools and capabilities

Copper exposes 31 MCP tools covering the board-design workflow, including:

- Creating and editing schematics with named net connections
- Searching LCSC and JLCPCB for stocked parts
- Importing symbols, footprints, and available 3D models
- Placing components and routing PCBs
- Applying length matching, differential-pair routing, width classes, and copper pours
- Running KiCad ERC and DRC checks
- Generating schematic, layer, and ray-traced 3D renders
- Producing Gerbers, drill files, BOMs, and placement files for JLCPCB, PCBWay, OSH Park, or generic fabrication

## Limitations and notes

Windows is tested end to end. The macOS and Linux installation paths are newer. Autorouting can download Freerouting and a Java runtime from GitHub and Adoptium, using about 120 MB once requested. The `npx` launcher may install Pillow from PyPI when KiCad's Python environment lacks it; the one-line installers also fetch uv, a Python 3.12 build, and Pillow.

Copper is an independent project and is not affiliated with KiCad, LCSC, JLCPCB, or other named vendors.

_Full upstream README: https://allmcps.com/mcp/copper-kicad-mcp/readme_